Reliance 10V4122( Electric GV3000 AC Drive)
May 28, 2026

Reliance 10V4122( Electric GV3000 AC Drive)

The 10V4122 is a 10 HP, 460V three-phase AC variable frequency drive (VFD) from Reliance Electric’s GV3000 series (now ABB/Baldor-Reliance). It is a high-performance, panel-mount drive for industrial motors, supporting both V/Hz and flux vector control (FVC/SVC) with precise speed/torque regulation.

Description

Product Description

The 10V4122 is a 10 HP, 460V three-phase AC variable frequency drive (VFD) from Reliance Electric’s GV3000 series (now ABB/Baldor-Reliance). It is a high-performance, panel-mount drive for industrial motors, supporting both V/Hz and flux vector control (FVC/SVC) with precise speed/torque regulation.

Model Definition

  • 10: 10 HP rating

  • V: GV3000 series (AC drive)

  • 4122: 460V, 3-phase, standard control code.

Technical Specifications

  • Manufacturer: Reliance Electric (ABB/Baldor-Reliance)

  • Series: GV3000 (GV3000/SE optional)

  • Motor Power: 10 HP (7.5 kW), 460 VAC, 3-phase

  • Input Voltage: 340–506 VAC, 3-phase, 48–62 Hz

  • Output Voltage: 0–460 VAC, 3-phase

  • Output Current: 14 A (continuous)

  • Control Modes: V/Hz (open-loop), FVC (closed-loop, encoder), SVC (sensorless vector)

  • Feedback: Encoder (optional), pulse tachometer

  • Communication: DeviceNet, ControlNet, RS232/485 (optional kits)

  • I/O: 8 digital inputs / 4 digital outputs, 2 analog inputs / 2 analog outputs

  • Environment: 0°C to +40°C, 5%–95% RH (non-condensing)

  • Enclosure: NEMA 1 (standard)

  • Status: Obsolete legacy unit (refurbished/surplus available).

Core Functions

  • Speed Regulation: ±0.01% (closed-loop FVC), ±0.5% (open-loop V/Hz)

  • Torque Control: 150% overload for 60 seconds, adjustable torque limit

  • Dynamic Response: 32-bit DSP, IGBT PWM (2/4/8 kHz carrier)

  • Fault Protection: Overcurrent, overvoltage, undervoltage, overtemperature, ground fault, short circuit

  • Parameter Storage: Non-volatile memory, password protection, fault log

  • Optional Features: Dynamic braking, line reactor, remote operator interface (OIM).

Compatibility

  • Motors: Standard 3-phase AC induction motors (NEMA/IEC)

  • Applications: Conveyors, pumps, fans, extruders, machine tools, process lines

  • Replacement: Direct replacement for GV3000 10HP 460V models (e.g., 10V4160).

Installation & Maintenance

  • Mounting: Panel-mount in clean, dry, ventilated enclosure; 150mm clearance top/bottom

  • Wiring: Separate AC input, motor output, and control wiring; shielded cables for control signals

  • Protection: Input circuit breaker, ground fault protection, ESD precautions

  • Maintenance: Periodic cleaning, connection checks, fan replacement; firmware update if needed.


Get a Quote