Honeywell 51304672-10
May 28, 2026

Honeywell 51304672-10

51304672-100 is the basic analog output card for Honeywell Experion PKS, TDC3000 and UCN systems, belonging to the HDW E series. This card can convert the digital signals issued by the controller into standard analog signals, which are used to drive on-site actuators, control valves and frequency converters, etc. It is mostly used as a spare part for old DCS systems.

Description

Product Introduction

51304672-100 is the basic analog output card for Honeywell Experion PKS, TDC3000 and UCN systems, belonging to the HDW E series. This card can convert the digital signals issued by the controller into standard analog signals, which are used to drive on-site actuators, control valves and frequency converters, etc. It is mostly used as a spare part for old DCS systems.

Model Interpretation

5130 represents the Honeywell TDC3000, UCN, and Experion PKS full series DCS products. 4672 is the category code for the analog output card. The suffix 100 corresponds to the R100 hardware version, which is the basic model, does not support redundancy functions, and only comes with basic fault diagnosis capabilities. Technical Specifications

Card integration: 8 analog output channels are provided by default. They can output 4 to 20 milliampere direct current signals, or be configured as 0 to 10 volt direct current signals. The signal accuracy is ±0.1% of the full scale. A 12-bit digital-to-analog conversion chip is used. In the current output mode, the maximum driving load is 500 ohms, and in the voltage output mode, the load is not less than 1000 ohms. The card only has channel-to-ground isolation. The withstand voltage rating is 1000 volts AC, lasting for one minute. The 24-volt DC power supply is provided by the backplane of the cabinet, with a voltage fluctuation range of ±10%. The overall power consumption is 4 to 5 watts. The operating temperature range is 0 degrees Celsius to 50 degrees Celsius, the storage temperature range is -40 degrees Celsius to 70 degrees Celsius, the relative humidity of the working environment is 5% to 95%, and condensation is prohibited inside the environment. The product is certified by CE and UL. Basic protection coating is applied to the surface, and the overall weight is approximately 0.35 kilograms. 

Interface and communication configuration: The card is connected to the system I/O bus through the backplane interface and completes data interaction with the controller. 8 analog output common terminals are set on the field side, without separately configured short-circuit protection function for channels. The equipment only supports board-level fault diagnosis and cannot separately detect open circuit, short circuit and overload abnormalities of each channel. This model does not support redundant configuration. The single card operates independently and supports hot-swapping operations. The replacement process will not affect the overall operation of the system. Core function

Convert digital signals to standard analog signals to meet the signal output requirements of conventional control loops. The overall power consumption is low, suitable for old cabinets with limited power supply capacity. The internal structure is streamlined, the operation is stable, the failure rate is low, and it has good compatibility with the early TDC3000 and UCN systems. Applicable scenarios

Compatible with Honeywell TDC3000, UCN and earlier versions of Experion PKS control systems. Widely applied in process industries such as petrochemicals, thermal power generation, water treatment, etc. Primarily used for signal output in non-critical control loops, often used for spare parts replacement of old equipment and analog drive for basic operating conditions.

User Manual for Use and Maintenance Use

Insert the card smoothly into the standard slot of the cabinet, ensuring a firm connection with the backplane. Connect the on-site equipment cables to the analog output terminals according to the design requirements, and confirm that the output signal type is correct. Complete the channel parameter configuration in the system software, and after the parameter download is completed, it can be put into use. Maintenance

Keep the interior of the cabinet dry and clean on a daily basis. Regularly inspect the connection terminals and promptly address any loose or oxidized issues. Utilize the system board-level diagnostic function to monitor the operation status of the cards. Unused spare parts should be placed in an anti-static bag and stored in a cool and dry area. Take precautions against static electricity during operation and handling. Do not disassemble the cards privately. Equipment maintenance should be carried out by professionals.