HONEYWELL 51304728-125
May 28, 2026

HONEYWELL 51304728-125

The 51304728-125 (51304728125) is a 16‑channel Galvanically Isolated Digital Input FTA (Field Terminal Assembly) for Honeywell TDC 3000, TPS, UCN, and Experion PKS DCS. It provides 250 VAC isolation, signal filtering, and surge protection for 24 VDC digital input signals. Designed for harsh industrial environments, it features a conformal‑coated PCB and gold‑plated screw terminals. Also known as MU‑GDID13.

Description

Product Description

The 51304728-125 (51304728125) is a 16‑channel Galvanically Isolated Digital Input FTA (Field Terminal Assembly) for Honeywell TDC 3000, TPS, UCN, and Experion PKS DCS. It provides 250 VAC isolation, signal filtering, and surge protection for 24 VDC digital input signals. Designed for harsh industrial environments, it features a conformal‑coated PCB and gold‑plated screw terminals. Also known as MU‑GDID13.

Model Definition

  • 5130: TDC 3000/UCN DCS series.

  • 4728: Digital Input FTA with galvanic isolation.

  • 125: 16 channels, conformal‑coated PCB, gold‑plated screw terminals, 250 VAC isolation, redundant compatible.

Technical Specifications

  • Channels: 16 single‑ended digital input channels.

  • Signal Type: 24 VDC dry contact or active high/low signals.

  • Isolation: 250 VAC RMS galvanic isolation (field‑to‑system).

  • Terminals: Gold‑plated screw terminals (field side); 50‑pin ribbon connector (system side).

  • Input Voltage: 24 VDC nominal, 18–30 VDC operating range.

  • Current Draw: ≤10 mA per channel.

  • Operating Temperature: -20°C to +60°C.

  • Storage Temperature: -40°C to +70°C.

  • Humidity: 5%–95% non‑condensing.

  • PCB Coating: Conformal‑coated (for corrosive/dusty environments).

  • Certifications: CE, UL, CSA, RoHS.

  • Form Factor: Size B, weight approx. 1.2 kg.

Interface and Communication Configuration

  • System Side: Connects to digital input IOPs (e.g., MC‑PDI02, 51304446‑150) via 50‑pin ribbon cable.

  • Field Side: 16 gold‑plated screw terminals for 24 VDC devices (switches, relays, proximity sensors).

  • Isolation: Full galvanic isolation eliminates ground loops and transient voltages.

  • Redundancy: Supports dual‑module redundancy for high‑availability systems.

  • Protocol: Passive FTA; no independent protocol. All processing/diagnostics via IOP and DCS.

Core Functions

  • Provides 16‑channel isolated digital input termination for 24 VDC field devices.

  • 250 VAC isolation protects DCS from electrical noise, ground faults, and voltage spikes.

  • Conformal‑coated PCB ensures reliability in humid, corrosive, or dusty environments.

  • Internal filtering and surge protection enhance signal stability and longevity.

  • Gold‑plated terminals resist oxidation and vibration, ensuring consistent connections.

  • Drop‑in compatible with TDC 3000/TPS/UCN/Experion PKS; hot‑swap capable.

Application Scenarios

  • Systems: Honeywell TDC 3000, TPS, UCN, Experion PKS DCS.

  • Industries: Oil & gas, chemical, petrochemical, power generation, pulp & paper, pharmaceuticals, offshore/coastal (high humidity/corrosion).

  • Field Devices: Limit switches, pressure switches, level switches, proximity sensors, relay contacts.

  • Installation: DCS control room cabinets, harsh‑environment local panels (corrosive, dusty, humid).

Usage and Maintenance Instructions

Usage

  • Mount in standard DCS cabinet with adequate wiring clearance and airflow.

  • Connect 50‑pin ribbon cable to matching digital input IOP; fully seat and lock.

  • Wire field devices to designated terminals, observing polarity; tighten to 0.8–1.0 N·m.

  • Power on DCS, verify no fault alarms, and confirm input status accuracy before commissioning.

Maintenance

  • Keep environment clean, dry, and well‑ventilated; avoid direct moisture or chemical exposure.

  • Inspect terminals and cables quarterly for tightness, corrosion, or damage; replace worn components.

  • Clean coated PCB and terminals only with dry soft cloth; no liquids or abrasives.

  • Store spares in anti‑static bags in cool, dry area.

  • Use ESD protection during handling; do not disassemble.


Get a Quote