HONEYWELL 51304748-175(MC-GAIH22)
May 28, 2026

HONEYWELL 51304748-175(MC-GAIH22)

The 51304748-175 (model MC-GAIH22) is a High-Level Analog Input FTA (Field Terminal Assembly) for Honeywell TDC 3000/TPS/UCN DCS, serving as the interface between high-level analog input modules (e.g., HLAI2/51304754 series) and field transmitters.

Description

Product Description

The 51304748-175 (model MC-GAIH22) is a High-Level Analog Input FTA (Field Terminal Assembly) for Honeywell TDC 3000/TPS/UCN DCS, serving as the interface between high-level analog input modules (e.g., HLAI2/51304754 series) and field transmitters.

Model Definition

  • 51304748-175: Official part number; 5130 = DCS series, 4748 = analog input FTA circuit, 175 = hardware revision.

  • MC-GAIH22: Alias (Galvanic Isolated Analog Input FTA).

  • Alternate P/N: 51304748175 (hyphen omitted).

Technical Specifications

  • Channels: 16 differential analog input terminals.

  • Signal Types: 4–20 mA (2-wire/self-powered), 1–5 VDC; compatible with HLAI2/MC-PAIH03 modules.

  • Isolation: Galvanic isolation between field and system; 1500 VAC withstand.

  • Terminals: Screw terminals for field wiring; gold-plated contacts for reliability.

  • Compatibility: Matches 51304754-100/150 (HLAI2/MC-PAIH03) modules.

  • Operating Temp: -20°C to +60°C; Storage: -40°C to +70°C.

  • Certifications: CE, UL, CSA, RoHS.

  • Weight: ~2 kg; Dimensions: 313 × 278 × 30 mm.

Core Functions

  1. Field Signal Interface: Transmit 16-channel 4–20 mA/1–5 VDC signals from transmitters to DCS input modules.

  2. Galvanic Isolation: Eliminate ground loops and suppress EMI for signal integrity.

  3. Wiring & Protection: Provide secure screw terminals; with surge/overvoltage protection.

  4. Module Matching: Dedicated FTA for HLAI2/MC-PAIH03 high-level analog input modules.

Application Scenarios

  • Industries: Oil/gas, chemical, petrochemical, power, pharmaceutical.

  • Uses: Connect pressure, temperature, flow, level transmitters in TDC 3000/TPS/UCN cabinets.

  • System: Honeywell TDC 3000, TPS, UCN DCS systems.

Usage & Maintenance

Usage

  1. Mount FTA in DCS cabinet, connect ribbon cable to HLAI2/MC-PAIH03 module.

  2. Wire field transmitters to FTA screw terminals (4–20 mA/1–5 VDC).

  3. Verify wiring integrity; power on and test signal communication.

Maintenance

  • Environment: Clean, dry, ventilated; temp/humidity within specs.

  • Inspection: Quarterly check of terminal tightness and cable condition.

  • Cleaning: Wipe dust with dry cloth; no liquid cleaners.

  • Storage: Spare FTAs in anti-static bags, cool/dry area.