Honeywell 51304638‑325 (51304638325)
Description
Technical Specifications
Part Number: 51304638‑325 (51304638325)
Alternative ID: MU‑GAOX12, 12‑Ch AO FTA, GI/IS Crimp, High‑Density Isolator
Module Type: Field Terminal Assembly (FTA), Analog Output Isolation (GI/IS)
System Compatibility: Honeywell UCN, TDC3000, TPS (LCN & UCN networks)
Output Channels: 12 isolated channels (4‑20 mA DC or 0‑10 VDC, sink/source configurable)
Isolation Rating: 1500 VAC (channel‑to‑backplane), 2500 VAC surge immunity
Resolution: 12‑bit (0.025% of full scale)
Accuracy: ±0.05% FS @ 25°C; ±0.1% FS over temperature range
Update Rate: 10 ms per channel
Load Resistance: 0–600 Ω (4‑20 mA); 0–10 kΩ (0‑10 VDC)
Power: 24 VDC ±10%, 180 mA (external or backplane‑fed)
Power Consumption: ~4.3 W
Operating Temperature: 0°C to +60°C (industrial standard, IS‑rated)
Storage Temperature: ‑40°C to +85°C
Humidity: 5%–95% RH, non‑condensing
Dimensions (H×W×D): 152 × 178 × 25 mm (7‑inch FTA, high‑density)
Weight: ~0.40 kg
Coating: Conformal coated (harsh environment grade, IS‑compliant)
Certifications: CE, RoHS, UL 508, ATEX II 3G Ex nA IIC T4 Gc (intrinsic safety)
Revisions: Common Rev S (hardware/firmware, IS‑enhanced)
Status: Active (new surplus/repair available; backward compatible with 51304638‑100/125/175/600)
Interface & Communication Configuration
Host Interface: UCN/TDC3000 backplane (proprietary, 1 Mbps)
Field Interface: 12 × crimp‑style screw terminals (GI/IS dual‑rated, isolated per channel)
Protocol Support: UCN analog output protocol; compatible with all Honeywell UCN analog controllers
Diagnostics: 2 on‑board LEDs (Power, Fault); remote alarm via UCN; channel‑specific fault logging (open/short circuit, IS fault detection)
Hot Swap: Yes (replace without system shutdown; auto‑reconnect in <5 seconds)
Compatibility: Drop‑in replacement for 51304638‑100/125/175/600; works with MC‑TAIH15, MC‑TDID72, and other UCN FTAs; supports IS crimp terminals for hazardous areas
Core Functions
High‑Density Isolation: 12‑channel galvanic isolation (vs 8‑channel standard) saves cabinet space for large I/O systems.
Dual‑Signal Output: Configurable for 4‑20 mA (current) or 0‑10 VDC (voltage) to support diverse field devices。
Intrinsic Safety (IS) Compliance: ATEX‑rated for hazardous areas (Zone 2), safe for flammable gas/vapor environments。
GI/IS Crimp Terminal Support: Dual‑rated terminals simplify wiring for both general and hazardous area applications。
Fault Protection & Diagnostics: Isolates channel faults; IS‑specific fault logging ensures safety in hazardous locations.
Application Scenarios
Hazardous Area Process Control: Refineries, chemical plants, and gas facilities (ATEX Zone 2) with flammable gases/vapors。
High‑I/O Density Loops: Large‑scale flow, pressure, temperature, and level control requiring 12 analog outputs.
Mixed Signal Systems: Facilities using both 4‑20 mA valves/actuators and 0‑10 VDC VFDs/indicators。
Legacy System Upgrades: Expanding TDC3000/TPS systems with high‑density, IS‑rated I/O.
Compatibility Note
System Compatibility: Honeywell UCN, TDC3000, TPS (requires UCN analog controller card)
Replacement Cross‑Reference:
51304638‑100: 8‑ch, standard, 0–55°C
51304638‑125: 8‑ch, enhanced, 0–60°C
51304638‑175: 8‑ch, high‑temp, ‑20°C to +70°C
51304638‑600: 8‑ch, high‑surge (3000 VAC)
51304638‑325: 12‑ch, GI/IS crimp, 0–60°C, ATEX‑rated
Key Difference (325 vs others): The 325 is the only 12‑channel model in the series, with intrinsic safety certification and GI/IS crimp terminals for hazardous area use。