Honeywell 51304540‑100 (51304540100)
May 28, 2026

Honeywell 51304540‑100 (51304540100)

Product Introduction Model: 51304540‑100 (Alias: 51304540100, LCNE2) Type: LCNE2 Fiber Optic Paddle Board (Local Control Network Extender) Manufacturer: Honeywell Series: TDC3000 / TPS DCS Description: The 51304540‑100 is an LCNE2 (LCN Extender) fiber‑optic paddle board for Honeywell TDC3000/TPS systems. It extends the LCN (Local Control Network) to remote locations via fiber optic cable, enabling long‑distance, high‑reliability communication between LCN nodes.

Description

Technical Specifications

  • Part Number: 51304540‑100 (51304540100)

  • Alternative ID: LCNE2 Paddle Board, LCN Extender, Fiber Optic Modem

  • Module Type: LCN Fiber Optic Extender (LCNE2)

  • System Compatibility: Honeywell TDC3000 / TPS (LCN network)

  • Processor: On‑board 16‑bit microcontroller

  • Memory: 128 KB RAM, 256 KB Flash (firmware)

  • Network Interface: LCN (1 Mbps, electrical); Fiber Optic (multi‑mode, 850 nm)

  • Fiber Type: Multi‑mode fiber (62.5/125 μm)

  • Max Distance: 2 km (multi‑mode fiber)

  • Power: 5 VDC ±5%, 500 mA (from backplane)

  • Power Consumption: ~2.5 W

  • Operating Temperature: 0°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Humidity: 5%–95% RH, non‑condensing

  • Dimensions (H×W×D): 178 × 127 × 25 mm

  • Weight: ~0.2 kg

  • Coating: Standard (non‑conformal)

  • Certifications: CE, RoHS compliant

  • Revisions: Common Rev G (hardware/firmware)

  • Status: Discontinued (replaced by XLCNE2)

Interface & Communication Configuration

  • Host Interface: LCN electrical (BNC, 75Ω) – connects to local LCN network

  • Fiber Interface: Dual SC/ST connectors (transmit/receive) for multi‑mode fiber

  • Redundancy: Supports redundant fiber paths (A/B) for fault tolerance

  • Diagnostics: 3 on‑board LEDs (Power, LCN Link, Fiber Status); remote alarm reporting via LCN

  • Hot Swap: Yes (replace without system shutdown)

  • Compatibility: Works with all TDC3000/TPS LCN nodes (HPM, APM, NIM, GUS)

Core Functions

  1. LCN Network Extension: Converts electrical LCN signals to fiber optic for long‑distance transmission.

  2. Signal Conversion: Electrical‑to‑optical (E/O) and optical‑to‑electrical (O/E) conversion.

  3. Data Transmission: Transmits LCN data at 1 Mbps over fiber, extending network range up to 2 km.

  4. Diagnostics & Monitoring: Monitors fiber link quality, signal strength, and module health; reports faults to system HMI.

  5. Redundancy Support: Enables redundant fiber paths to ensure continuous communication in case of fiber breakage.

  6. Isolation: Provides electrical isolation between local and remote LCN segments, reducing noise and interference.

Application Scenarios

  • TDC3000/TPS DCS: Extending LCN to remote control rooms, field sites, or buildings.

  • Large‑Scale Process Plants: Chemical, petrochemical, oil & gas, power generation, pulp & paper (wide‑area LCN coverage).

  • Harsh Environments: Industrial areas with high electrical noise, EMI/RFI interference, or long cable runs.

  • Legacy System Upgrades: Replacing aging LCNE1 modules or extending existing LCN networks without full system replacement.

Compatibility Note

  • System Compatibility: Honeywell TDC3000/TPS (LCN network mandatory)

  • Replacement: 51304540‑100 (LCNE2) → XLCNE2 (current replacement model)

  • Firmware: Requires TDC3000 firmware Rev 300+ for full LCNE2 functionality

  • Key Difference: LCNE2 (51304540‑100) = Multi‑mode fiber (2 km); LCNE1 = Single‑mode fiber (10 km)


Get a Quote