Honeywell 51304516‑200 (51304516200)
Description
Technical Specifications
Part Number: 51304516‑200 (51304516200)
Alternative ID: MU‑PSTX03
Module Type: UCN Smart Multivariable Transmitter Interface (STIM IOP CE)
Network: UCN (Universal Control Network), 1 Mbps
Field Protocols: HART 5/7 (multivariable), Honeywell Smart Protocol
Channel Capacity: 16 isolated 4–20 mA/HART channels (multidrop, multi‑variable capable)
Signal Input: 4–20 mA analog + digital HART overlay (supports up to 8 variables per transmitter)
Power: 24 VDC ±10%, 150 mA (backplane)
Power Consumption: ~3.6 W
Operating Temperature: 0°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5%–95% RH, non‑condensing
Dimensions (H×W×D): 220 × 120 × 30 mm
Weight: ~0.4 kg
Coating: Standard (non‑conformal)
Certifications: CE, RoHS compliant
Revisions: Common Rev B, C, H (hardware); Rev B (firmware)
Status: Discontinued (legacy replacement only)
Interface & Communication Configuration
Host Interface: UCN network (75Ω coaxial, redundant A/B)
Field Interface: 16 × 4–20 mA/HART isolated channels (screw terminals)
Redundancy: UCN A/B redundancy supported; field channels non‑redundant
Diagnostics: On‑board LEDs for UCN link, power, and channel status; remote alarm reporting for multi‑variable faults
Wiring: Shielded twisted pair (STP) for field transmitters; 75Ω coax for UCN
Hot Swap: Yes (replace without system shutdown)
FTA Compatibility: MU‑TAIH03 / MC‑TAIH03 (16‑channel HART multivariable FTA)
Core Functions
Multivariable Transmitter Integration: Connects HART multivariable transmitters (e.g., Coriolis mass flow, differential pressure with temperature compensation) to TDC3000 UCN.
Multi‑Parameter Data Acquisition: Captures up to 8 process variables per transmitter (e.g., mass flow, density, temperature, pressure) in addition to 4–20 mA analog.
Multidrop Communication: Up to 16 multivariable devices per card, reducing wiring and hardware costs for complex field networks.
Digital Configuration & Calibration: Remote setup, calibration, and parameter adjustment for all variables via HART.
Advanced Diagnostics: Monitors transmitter health, detects faults (open circuit, overrange, variable mismatch), and reports detailed diagnostics to DCS.
Protocol Conversion: Translates HART multivariable protocol to UCN for seamless system integration.
Application Scenarios
TDC3000/TPS DCS: Primary interface for HART multivariable transmitters in process industries.
Process Plants: Chemical, petrochemical, oil & gas, power, pulp & paper (applications requiring multi‑parameter measurement).
Multivariable Instrumentation: Coriolis flowmeters, DP transmitters with temperature compensation, level transmitters with density measurement.
Legacy System Modernization: Upgrading analog‑only DCS to digital multivariable smart instrumentation.
CE‑Compliant Plants: Required for European Union installations.
Compatibility Note
System Compatibility: Honeywell TDC3000/TPS (UCN network required)
Field Device Compatibility: HART 5/7 multivariable, Honeywell ST3000 smart transmitters
Replacement: Direct upgrade for 51304516‑100 (single‑variable); 51304516‑250 is conformal‑coated version (MC‑PSTX03)
Firmware: Requires TDC3000 firmware Rev 400+ for full HART multivariable support
Key Difference: 51304516‑200 = Multivariable + CE; 51304516‑100 = Single‑variable + CE; 51304516‑250 = Multivariable + CE + Conformal Coating