Description
Technical Specifications
Part Number: 51304443-100 (51304443100)
Module Type: MU-TDOR12 (Relay Output FTA)
Channel Configuration: 16 × independent electromechanical relay outputs (dry contact)
Load Voltage Rating: 120 VAC / 125 VDC (max)
Contact Rating: 6 A per channel (resistive load), 1/3 HP at 120 VAC
Isolation: 1500 VAC rms (channel‑to‑backplane)
Response Time: ≤10 ms per channel
Power Supply: 24 VDC ±10%, 0.3 A (backplane‑powered)
Operating Temperature: -20°C to +60°C (standard environment)
Storage Temperature: -40°C to +85°C
Humidity: 5%–95% RH, non‑condensing
Dimensions (H×W×D): 270 × 185 × 95 mm (Size C, 18‑inch form factor)
Weight: ~2.3 kg
Certifications: UL‑listed (no CE/RoHS)
Coating: Basic conformal coating (standard protection)
Terminals: Compression‑type (12–22 AWG, non‑vibration‑resistant)
Status Indicators: Power/Fault LED, individual channel status LEDs
Current Draw: ≤3.6 W
Vibration Resistance: 2g, 10–500 Hz (standard industrial tolerance)
Interface & Communication Configuration
DCS Interface: UCN backplane edge connector (1 Mbps, TDC3000/TPS/Experion PKS compatible)
Field Interface: Compression‑type terminals (16 channels for 120 VAC/125 VDC loads)
Redundancy: Supports redundant IOP (Input/Output Processor) configurations
Diagnostics: On‑board self‑diagnostics with fault reporting via UCN; LED status for quick troubleshooting
Wiring: Accepts 12–22 AWG stranded copper wire
Connector: UCN 96‑pin edge connector (gold‑plated contacts)
Core Functions
16‑Channel Relay Output Switching: Controls high‑power field devices (motor starters, solenoids, alarms, actuators) via dry‑contact relays.
High‑Voltage Isolation: 1500 VAC isolation protects DCS from load‑side electrical noise and voltage spikes.
Standard Environment Protection: Basic conformal coating safeguards against dust and moisture in non‑harsh areas.
UL Compliance: Meets UL safety standards for industrial deployments.
Backplane‑Powered: Draws power from UCN backplane, eliminating external power supplies.
Status Monitoring: Individual channel LEDs enable quick visual status checks.
Application Scenarios
Process Industries: Standard chemical, petrochemical, power generation, pulp & paper facilities (non‑harsh environments).
High‑Power Device Control: 120 VAC/125 VDC motor starters, solenoid valves, alarm beacons, and heavy‑duty actuators.
Legacy DCS Systems: Replacement/expansion for Honeywell TDC3000/TPS installations in standard plant areas.
Non‑Corrosive Zones: Indoor control rooms, dry manufacturing floors, and low‑humidity facilities.
Cost‑Sensitive Projects: Applications requiring basic relay output functionality without CE/RoHS or extreme environment features.
Compatibility Note
Form‑factor compatible with other 51304443 series (Size C, UCN connector).
Functionally compatible with 51309148 series (16‑channel relay output, UCN protocol).
Recommended for legacy TDC3000/TPS systems needing 120 VAC/125 VDC relay outputs in standard non‑harsh environments.