Honeywell 51304441-275 (MC-TDID52)
May 28, 2026

Honeywell 51304441-275 (MC-TDID52)

Product Introduction Model: 51304441-275 (Alias: 51304441275, MC-TDID52) Type: 32‑Channel Isolated Digital Input FTA (Field Termination Assembly) Manufacturer: Honeywell Series: TDC3000 / TPS UCN DCS, MC Series I/O Description: The 51304441-275 (MC-TDID52) is a 24 VDC, 32‑channel isolated digital input FTA with enhanced+ conformal coating, heavy‑duty screw terminals, CE/UL/RoHS compliance, built for ultra‑extreme harsh industrial environments in Honeywell TDC3000/TPS and Experion PKS systems. It delivers high‑density discrete input monitoring with 1500 VAC channel‑to‑backplane isolation and maximum protection for corrosive, humid, high‑vibration, or extreme‑temperature zones.

Description

Technical Specifications

  • Part Number: 51304441-275 (51304441275)

  • Module Type: MC-TDID52 (Digital Input FTA)

  • Channel Configuration: 32 × galvanically isolated digital input channels

  • Input Voltage: 24 VDC ±10% (dry contact or wet DC voltage)

  • Isolation: 1500 VAC rms (channel‑to‑backplane)

  • Response Time: ≤5 ms per channel (supports SOE recording)

  • Power Supply: 24 VDC ±10%, 0.5 A (backplane‑powered)

  • Operating Temperature: -40°C to +75°C (ultra‑extreme harsh rating)

  • Storage Temperature: -40°C to +85°C

  • Humidity: 5%–95% RH, non‑condensing (corrosion‑resistant coating)

  • Dimensions (H×W×D): 270 × 185 × 95 mm (Size C, 18‑inch form factor)

  • Weight: ~1.4 kg (compact reinforced housing)

  • Certifications: CE‑compliant, UL‑listed, RoHS‑compliant

  • Coating: Enhanced+ conformal coating (ultra‑extreme harsh environment protection)

  • Terminals: Heavy‑duty screw‑type (12–22 AWG, vibration‑resistant)

  • Status Indicators: Power/Fault LED, individual channel status LEDs

  • Current Draw: ≤4.0 W

  • Vibration Resistance: 5g, 10–500 Hz (industrial vibration tolerance)

Interface & Communication Configuration

  • DCS Interface: UCN backplane edge connector (1 Mbps, TDC3000/TPS/Experion PKS compatible)

  • Field Interface: Heavy‑duty screw terminals (32 channels for 24 VDC inputs)

  • Redundancy: Supports redundant IOP (Input/Output Processor) configurations

  • Diagnostics: On‑board self‑diagnostics with fault reporting via UCN; LED status for quick troubleshooting

  • Wiring: Accepts 12–22 AWG stranded copper wire (heavy‑gauge compatibility)

  • Connector: UCN 96‑pin edge connector (gold‑plated contacts for reliability)

Core Functions

  1. 24 VDC Digital Input Monitoring: Captures low‑voltage discrete signals from switches, relays, and sensors (32‑channel high density for ultra‑extreme environments).

  2. Galvanic Isolation: 1500 VAC isolation protects DCS from electrical noise, ground loops, and voltage spikes in harsh plants.

  3. Fast Response: 5 ms response time enables accurate sequence‑of‑events (SOE) logging for critical process troubleshooting.

  4. Enhanced+ Conformal Coating: Provides superior protection against moisture, dust, corrosive gases, and chemical vapors (ideal for chemical/petrochemical/offshore zones).

  5. CE/UL/RoHS Compliance: Meets global safety and environmental standards for international deployments.

  6. Heavy‑Duty Termination: Vibration‑resistant screw terminals for high‑vibration areas (e.g., power plants, heavy machinery zones).

  7. Ultra‑Extended Temperature Range: Operates reliably at up to +75°C and down to -40°C for the most extreme industrial environments.

Application Scenarios

  • Process Industries: Chemical, petrochemical, power generation, pulp & paper, offshore oil & gas (ultra‑extreme harsh environments requiring CE/UL/RoHS).

  • Harsh Environment Monitoring: Outdoor installations, high‑humidity areas, corrosive industrial zones, high‑vibration facilities, and extreme‑temperature zones.

  • Low‑Voltage Device Monitoring: 24 VDC limit switches, proximity sensors, relay contacts, and panel status lights in ultra‑harsh conditions.

  • Legacy DCS Systems: Replacement/expansion for Honeywell TDC3000/TPS installations in harsh plant areas.

  • Global Deployments: Facilities requiring CE, UL, and RoHS markings for compliance.

  • Ultra‑Extreme Temperature Zones: Industrial areas with ambient temperatures ranging from -40°C to +75°C.

Key Differences: 51304441 Series Variants

Feature51304441-10051304441-12551304441-17551304441-20051304441-22551304441-275
Revision100125175200225275
SeriesMU-TDID12MU-TDID12MC-TDID12MU-TDID52MC-TDID52MC-TDID52
Input Voltage24 VDC24 VDC24 VDC24 VDC24 VDC24 VDC
Conformal Coating❌ No❌ No✅ Standard✅ Enhanced✅ Enhanced+✅ Enhanced+
CE Certified❌ No✅ Yes✅ Yes✅ Yes✅ Yes✅ Yes
UL Certified❌ No❌ No✅ Yes✅ Yes✅ Yes✅ Yes
RoHS Compliant❌ No❌ No❌ No✅ Yes✅ Yes✅ Yes
TerminalsCompressionCompressionCompressionHeavy‑Duty CompressionHeavy‑Duty ScrewHeavy‑Duty Screw
Operating Temp-20°C~+60°C-20°C~+60°C-20°C~+60°C-20°C~+70°C-40°C~+70°C-40°C~+75°C
EnvironmentStandardStandard (CE)Harsh (CE/UL)Extreme Harsh (CE/UL/RoHS)Ultra Extreme Harsh (CE/UL/RoHS)Ultra Extreme+ Harsh (CE/UL/RoHS)

Compatibility Note

  • Form‑factor compatible with other 51304441 series (Size C, UCN connector).

  • Functionally compatible with 51304439 series (32‑channel isolated input, UCN protocol, different voltage).

  • Recommended for legacy TDC3000/TPS systems needing 24 VDC inputs in ultra‑extreme+ harsh environments with CE/UL/RoHS compliance.