Honeywell 51304441-175 (MC-TDID12)
Description
Technical Specifications
Part Number: 51304441-175 (51304441175)
Module Type: MC-TDID12 (Digital Input FTA)
Channel Configuration: 32 × galvanically isolated digital input channels
Input Voltage: 24 VDC ±10% (dry contact or wet DC voltage)
Isolation: 1500 VAC rms (channel‑to‑backplane)
Response Time: ≤2 ms per channel (supports SOE recording)
Power Supply: 24 VDC ±10%, 0.5 A (backplane‑powered)
Operating Temperature: -20°C to +60°C (rated for harsh environments)
Storage Temperature: -40°C to +85°C
Humidity: 5%–95% RH, non‑condensing
Dimensions (H×W×D): 270 × 185 × 95 mm (Size C)
Weight: ~2.4 kg
Certifications: CE‑compliant, UL‑listed
Coating: Conformal coated (harsh environment protection)
Terminals: Compression‑type (14–22 AWG)
Status Indicators: Power/Fault LED, channel status LEDs
Current Draw: ≤3.5 W
Interface & Communication Configuration
DCS Interface: UCN backplane edge connector (1 Mbps, TDC3000/TPS/Experion PKS compatible)
Field Interface: Compression terminals (32 channels for 24 VDC inputs)
Redundancy: Supports redundant IOP configurations
Diagnostics: On‑board self‑diagnostics with fault reporting via UCN
Wiring: Accepts 14–22 AWG stranded copper wire
Connector: UCN 96‑pin edge connector
Core Functions
24 VDC Digital Input Monitoring: Captures low‑voltage discrete signals from switches, relays, and sensors (32‑channel high density)。
Galvanic Isolation: 1500 VAC isolation protects DCS from electrical noise and ground loops.
Fast Response: 2 ms response time enables accurate sequence‑of‑events (SOE) logging.
Conformal Coating: Protects against moisture, dust, and corrosive gases for harsh environments。
CE/UL Compliance: Meets European and North American safety standards for global deployments。
High Density: 32 channels reduce cabinet space requirements。
Application Scenarios
Process Industries: Chemical, petrochemical, power generation, pulp & paper (harsh environments, CE/UL required)。
Harsh Environment Monitoring: Outdoor installations, high‑humidity areas, or corrosive industrial zones。
Low‑Voltage Device Monitoring: 24 VDC limit switches, proximity sensors, relay contacts, and panel status lights。
Legacy DCS Systems: Replacement/expansion for Honeywell TDC3000/TPS installations。
Global Deployments: Facilities requiring both CE and UL markings for compliance。
Key Differences: 51304441 Series Variants
| Feature | 51304441-100 | 51304441-125 | 51304441-175 |
|---|---|---|---|
| Revision | 100 | 125 | 175 |
| Series | MU-TDID12 | MU-TDID12 | MC-TDID12 |
| Input Voltage | 24 VDC | 24 VDC | 24 VDC |
| Conformal Coating | ❌ No | ❌ No | ✅ Yes |
| CE Certified | ❌ No | ✅ Yes | ✅ Yes |
| UL Certified | ❌ No | ❌ No | ✅ Yes |
| Terminals | Compression | Compression | Compression |
| Operating Temp | -20°C~+60°C | -20°C~+60°C | -20°C~+60°C |
| Environment | Standard | Standard (CE) | Harsh (CE/UL) |
Compatibility Note
Form‑factor compatible with other 51304441 series (Size C, UCN connector).
Functionally compatible with 51304439 series (32‑channel isolated input, UCN protocol, different voltage).
Recommended for legacy TDC3000/TPS systems needing 24 VDC inputs in harsh environments with CE/UL compliance.
Get a Quote