Honeywell 51304441-100 (MU-TDID12)
May 28, 2026

Honeywell 51304441-100 (MU-TDID12)

Product Introduction Model: 51304441-100 (Alias: 51304441100, MU-TDID12) Type: 32‑Channel Isolated Digital Input FTA (Field Termination Assembly) Manufacturer: Honeywell Series: TDC3000 / TPS UCN DCS, MU Series I/O Description: The 51304441-100 (MU-TDID12) is a 24 VDC, 32‑channel isolated digital input FTA with compression terminals, designed for standard industrial environments in Honeywell TDC3000/TPS and Experion PKS systems. It provides high‑density, low‑voltage discrete input monitoring with 1500 VAC channel‑to‑backplane isolation.

Description

Technical Specifications

  • Part Number: 51304441-100 (51304441100)

  • Module Type: MU-TDID12 (Digital Input FTA)

  • Channel Configuration: 32 × galvanically isolated digital input channels

  • Input Voltage: 24 VDC ±10% (dry contact or wet DC voltage)

  • Isolation: 1500 VAC rms (channel‑to‑backplane)

  • Response Time: ≤2 ms per channel (supports SOE recording)

  • Power Supply: 24 VDC ±10%, 0.5 A (backplane‑powered)

  • Operating Temperature: -20°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Humidity: 5%–95% RH, non‑condensing

  • Dimensions (H×W×D): 270 × 185 × 95 mm (Size C)

  • Weight: ~2.4 kg

  • Certifications: Non‑CE, Non‑UL

  • Coating: Non‑conformal coated (standard environment)

  • Terminals: Compression‑type (14–22 AWG)

  • Status Indicators: Power/Fault LED, channel status LEDs

  • Current Draw: ≤3.5 W

Interface & Communication Configuration

  • DCS Interface: UCN backplane edge connector (1 Mbps, TDC3000/TPS/Experion PKS compatible)

  • Field Interface: Compression terminals (32 channels for 24 VDC inputs)

  • Redundancy: Supports redundant IOP configurations

  • Diagnostics: On‑board self‑diagnostics with fault reporting via UCN

  • Wiring: Accepts 14–22 AWG stranded copper wire

  • Connector: UCN 96‑pin edge connector

Core Functions

  1. 24 VDC Digital Input Monitoring: Captures low‑voltage discrete signals from switches, relays, and sensors (32‑channel high density).

  2. Galvanic Isolation: 1500 VAC isolation protects DCS from electrical noise and ground loops.

  3. Fast Response: 2 ms response time enables accurate sequence‑of‑events (SOE) logging.

  4. Compression Termination: Secure, vibration‑resistant wiring for standard industrial environments.

  5. High Density: 32 channels reduce cabinet space requirements.

Application Scenarios

  • Process Industries: Chemical, petrochemical, power generation, pulp & paper (standard environments, non‑CE/non‑UL).

  • Low‑Voltage Device Monitoring: 24 VDC limit switches, proximity sensors, relay contacts, and panel status lights.

  • Legacy DCS Systems: Replacement/expansion for Honeywell TDC3000/TPS installations.

  • Space‑Constrained Cabinets: High‑density I/O reduces footprint.

Key Differences: 51304441 Series Variants

Feature51304441-10051304441-12551304441-175
Revision100125175
SeriesMU-TDID12MU-TDID12MC-TDID12
Input Voltage24 VDC24 VDC24 VDC
Conformal Coating❌ No❌ No✅ Yes
CE Certified❌ No✅ Yes✅ Yes
UL Certified❌ No❌ No✅ Yes
TerminalsCompressionCompressionCompression
Operating Temp-20°C~+60°C-20°C~+60°C-20°C~+60°C
EnvironmentStandardStandardHarsh

Compatibility Note

  • Form‑factor compatible with other 51304441 series (Size C, UCN connector).

  • Functionally compatible with 51304439 series (32‑channel isolated input, UCN protocol, different voltage).

  • Recommended for legacy TDC3000/TPS systems needing 24 VDC inputs in standard environments.


Get a Quote