Honeywell 51304427-150 (MC-TDOR22)
Description
Technical Specifications
Part Number: 51304427-150 (51304427150)
Module Type: MC-TDOR22 (Digital Output Relay FTA)
Channel Configuration: 16 × SPDT relay outputs (independent)
Contact Rating: 240 VAC / 125 VDC, 5 A resistive per channel (same as -100)
Isolation: 1500 VAC rms channel‑to‑backplane isolation
Input Logic: 24 VDC from UCN HPM/APM controller
Power Supply: 24 VDC ±10%, 1.0 A (backplane‑powered)
Fuse: 6 A SB (system board fuse, replaceable)
Operating Temperature: -20°C to +60°C (extended range vs -100)
Storage Temperature: -40°C to +85°C
Humidity: 5%–95% RH, non‑condensing
Dimensions (H×W×D): 307 × 120 × 50 mm (12‑inch size B, same as -100)
Weight: ~2.1 kg (slightly heavier due to coating)
Certifications: CE, UL, RoHS (-100 is non‑CE)
Coating: Conformal coated (protects against dust, moisture, corrosion)
Status Indicators: 16 channel LEDs + Power/Fault LEDs
Response Time: ≤10 ms (per relay)
Interface & Communication Configuration
DCS Interface: UCN backplane via edge connector (1 Mbps, TDC3000/TPS compatible)
Field Interface: Compression‑type screw terminals (16 channels: common + NC + NO)
Redundancy: Non‑redundant (same as -100; no dual‑controller input support)
Diagnostics: On‑board self‑diagnostics with fault reporting to DCS via UCN
Wiring: Accepts 14–22 AWG stranded copper wire
Core Functions
Relay Output Switching: 16 independent SPDT relays for direct control of field loads (valves, pumps, solenoids).
Field Termination: Centralizes digital output wiring from DCS IOPs to field devices.
Electrical Isolation: Protects DCS from field‑side voltage spikes, noise, and ground loops.
Status Monitoring: Per‑channel LEDs for instant visual verification of output state.
Harsh Environment Protection: Conformal coating ensures reliability in dusty/humid industrial areas.
Application Scenarios
Process Industries: Chemical, petrochemical, oil & gas, power generation, pulp & paper.
Field Device Control: On/off control of valves, pumps, fans, motors, and solenoids (≤5 A).
Alarm Systems: Driving audible/visual alarms for process events.
Interlock Circuits: Non‑safety interlocks (non‑SIL rated) for process control.
Harsh Environments: Ideal for outdoor or high‑humidity areas (due to conformal coating).
Key Differences: 51304427-150 vs 51304427-100
| Feature | 51304427-150 (MC-TDOR22) | 51304427-100 (MU-TDOR22) |
|---|---|---|
| Revision | 150 (Updated) | 100 (Original) |
| Series | MC (Revised MU) | MU (Legacy) |
| Conformal Coating | ✅ Yes | ❌ No |
| CE/UL Certified | ✅ Yes | ❌ No |
| Operating Temp | -20°C to +60°C | -20°C to +60°C |
| Weight | ~2.1 kg | ~2.0 kg |
| Reliability | Higher (coated, certified) | Standard (uncoated, non‑certified) |
Compatibility Note
Fully pin‑compatible with 51304427-100; direct drop‑in replacement for TDC3000/TPS UCN racks.
Recommended for new installations or replacements in harsh environments (prefer -150 over -100).
Get a Quote