3IF772.9 Network Module Detailed Product Description
May 27, 2026

3IF772.9 Network Module Detailed Product Description

3IF772.9 is a aPCI bus dual CAN+RS232 network communication module of B&R SYSTEM 2005 platform. It is designed for complex industrial communication scenarios involving multiple devices and multiple protocols. The module integrates two independent and electrically isolated CAN-Bus interfaces and one configurable RS232 interface. It is plug-in type, supports hot swapping, is suitable for the harsh environment of control cabinets, and can simultaneously build redundant CAN networks, connect CANopen devices and serial port terminals. It is a core expansion component for achieving multi-bus integration, distributed control and device networking.

Description

3IF772.9 Network Module Detailed Product Description
 Product Introduction

3IF772.9 is a aPCI bus dual CAN+RS232 network communication module of B&R SYSTEM 2005 platform. It is designed for complex industrial communication scenarios involving multiple devices and multiple protocols. The module integrates two independent and electrically isolated CAN-Bus interfaces and one configurable RS232 interface. It is plug-in type, supports hot swapping, is suitable for the harsh environment of control cabinets, and can simultaneously build redundant CAN networks, connect CANopen devices and serial port terminals. It is a core expansion component for achieving multi-bus integration, distributed control and device networking. Basic Information

Product model: 3IF772.9, Brand: B&R Beagle, Belong to SYSTEM 2005 series aPCI network module. Product type: Dual CAN + RS232 multi-interface network communication module. Installation method: Direct insertion. Compatible with 2005 series CPU and IF060, IF260 standard IF slots. Width of the shape is approximately 35mm, height is 126.1mm, depth is 54mm, protection level is IP20. Limited to indoor control cabinet installation. Working power supply is provided by the back panel: 3.3VDC and 5VDC. Total power consumption is approximately 2.0W. No external power supply is required. Certified by CE, UKCA, EAC, etc. Compliant with EMC and safety standards. Suitable for long-term stable operation scenarios.

Function and positioning

This module serves as the multi-protocol network core expansion unit of SYSTEM 2005 PLC, integrating dual CAN buses and RS232 interfaces, achieving parallel and redundant communication of multiple buses. Both CAN-Bus interfaces are electrically isolated, supporting CAN 2.0A/B and CANopen master/slave stations, with a maximum of 500kbps per path. It can build redundant CAN networks or connect multiple CANopen servo, frequency converters, and remote I/O. The RS232 interface can be configured as an online debugging or data transmission interface, connecting to the upper computer or serial port terminal to achieve program download, monitoring, and data interaction. Interconnections between interfaces and between interfaces and the system bus are electrically isolated, with strong anti-interference ability; supports hot swapping, maintenance without power-off; configured through Automation Studio for CAN baud rate, node address, and RS232 parameter settings, suitable for redundant CAN networks, multi-CAN device networking, serial port online debugging, and upgrading of old equipment to multiple protocols.

Core performance parameters

Communication interfaces include 2 CAN-Bus (4-pin terminal connectors), 1 RS232 (DB9 female connector), all interfaces are electrically isolated. Supported protocols: CAN 2.0A/B, CANopen master/slave stations, RS232 asynchronous communication. CAN transmission rate up to 500kbps (10kbps–500kbps adjustable), RS232 up to 115.2kbps. CAN bus topology is linear, single network segment up to 110 nodes, transmission distance 1000 meters (10kbps) to 40 meters (500kbps); RS232 maximum 15 meters. Data processing: CAN receive and transmit bidirectional object buffering, supports PDO/SDO communication, flexible process data throughput. Power consumption is approximately 2.0W. Operating temperature range is 0℃ to + 60℃, storage temperature range is -25℃ to + 70℃, relative humidity 5%–95% without condensation. Panel LED indicators display CAN activity, faults, RS232 reception and transmission, and power status, supporting rapid diagnosis. Configuration method is through Automation Studio software configuration.

General adapter accessories

Communication cables are compatible with CAN-Bus shielded twisted pair and RS232 shielded cables; connection accessories include 4-pin CAN terminal connectors, DB9 shielded connectors, CAN terminal resistors; optional accessories include SYSTEM 2005 standard backplane (6/9/12 slots), DIN rail kit; software tools include Automation Studio, CANopen configuration tool, bus monitoring and serial port debugging tool. Applicable equipment fields

Widely used in SYSTEM 2005 PLC control system, CANopen distributed I/O, redundant CAN network; compatible with CANopen servo/variable frequency network connection, PLC and CAN sensors/indicators interaction, serial port online debugging; matched with CNC machines, industrial robots, packaging machinery, textile equipment, injection molding machinery; applied to CAN bus control and data acquisition of construction machinery, rail transportation, new energy equipment; compatible with redundant CAN network construction, multi-protocol communication expansion, and renovation of old equipment, etc.