Model: 086466-060W (also 0-86466-060W / 86466-60W) Manufacturer: Reliance Electric (ABB/Baldor‑Reliance) Type: 3‑Phase SCR Rectifier Stack (MaxPak Plus Series) Overview: 460V, 60A DC controlled rectifier stack; same power rating as ‑060R, but with four gate coupling boards (vs two on R/S suffix).

Description

Technical Specifications

  • Part Number: 086466-060W (0-86466-060W / 86466-60W)

  • Input Voltage: 3‑phase 460 VAC (380–480 VAC)

  • Frequency: 50 / 60 Hz

  • Output: 6‑pulse full‑wave controlled DC

  • DC Current Rating: 60 A continuous (matches “‑060‑”)

  • Thyristors: Press‑pack SCRs, high surge/long life

  • Heat Sinks: Dual finned aluminum, bolted central carrier

  • Gate Boards: Four 0‑51378‑19 coupling boards (transformer, resistors, diodes)

  • Protection: MOVs, RC snubbers, overcurrent sensing

  • Mounting: Chassis‑mount, vertical airflow

  • Weight: ~22.7 kg (50 lbs)

  • Dimensions (W×H×D): 350 × 200 × 150 mm

  • Insulation: Class F (155°C)

Key Differences vs 086466-060R

  • ‑060W: 4 gate boards (for redundancy / parallel drive setups)

  • ‑060R: 2 gate boards (standard single‑drive use)

  • Form/Fit: Mechanically interchangeable; same footprint/connections

Key Features

  • 60A Continuous DC: For large DC motors and high‑current loads.

  • Quad Gate Boards: Built‑in redundancy, ideal for critical/parallel systems.

  • Press‑Pack SCRs: High reliability for 100% duty cycle.

  • Dual Heat Sinks: Efficient cooling for heavy industrial use.

  • Spike Suppression: MOVs/RC networks protect SCRs from transients.

Applications

  • DC Motor Drives: Conveyors, cranes, extruders, rolling mills (60A).

  • Parallel/Redundant Systems: Where dual control channels are required.

  • Industrial DC Power: Plating, electrolysis, heating.

  • Retrofits/Spare Parts: Reliance MaxPak Plus, GV3000/6000 DC buses.

Compatible Drives

  • Reliance MaxPak Plus DC Drives

  • Reliance GV3000 / GV6000 (DC bus assemblies)

  • ABB/Baldor‑Reliance 460V DC drive systems

Installation & Maintenance

Mounting

  • Vertical only; 100 mm clearance above heat sinks.

  • Torque mounting bolts to 4.5 Nm; ensure good chassis ground.

Wiring

  • AC Input: L1, L2, L3 (460V 3‑phase)

  • DC Output: +DC, −DC (to armature/load)

  • Gate Signals: To/from drive control board via 0‑51378‑19 cables.

Maintenance

  • Clean heat sinks quarterly (compressed air).

  • Check gate board connections annually (1.2 Nm torque).

  • Test SCR leakage every 2 years; replace if >5 mA at full voltage.


Get a Quote