086466-060R
May 27, 2026

086466-060R

Model: 086466-060R (also 0-86466-060R / 86466-60R) Manufacturer: Reliance Electric (ABB/Baldor-Reliance) Type: 3‑Phase SCR Rectifier Stack (MaxPak Plus Series) Overview: Heavy‑duty 460V AC‑to‑DC thyristor rectifier for industrial DC drives, designed for high‑current, continuous operation in demanding environments.

Description

Technical Specifications

  • Part Number: 086466-060R (0-86466-060R / 86466-60R)

  • Input Voltage: 3‑phase 460 VAC (380–480 VAC)

  • Frequency: 50 / 60 Hz

  • Output: Full‑wave controlled DC

  • Thyristor Configuration: 6‑pulse bridge, press‑pack SCRs

  • Heat Sinks: Dual finned aluminum, bolted central carrier

  • Gate Boards: Two 0‑51378‑19 coupling boards (transformer, resistors, diodes)

  • Protection: MOVs, RC snubbers, overcurrent sensing

  • Mounting: Chassis‑mount, vertical airflow

  • Weight: ~22.7 kg (50 lbs)

  • Dimensions (W×H×D): 350 × 200 × 150 mm

  • Insulation: Class F (155°C)

  • Current Rating: 60 ADC continuous (matches “‑060‑” in part number)

Key Features

  • 60A Continuous DC: High current for large DC motors and loads.

  • Press‑Pack SCRs: High surge capability, long service life.

  • Dual Heat Sinks: Optimized cooling for 100% duty cycle.

  • Integrated Gate Boards: Pre‑assembled 0‑51378‑19 cards for fast installation.

  • Spike Suppression: MOVs and RC networks protect SCRs from transients.

  • Drop‑In Compatible: Replaces 86466-58S / 59S / 60S in MaxPak Plus systems.

Applications

  • DC Motor Drives: Conveyors, cranes, extruders, rolling mills (up to 60A).

  • Industrial DC Power Supplies: Plating, electrolysis, heating.

  • Retrofits & Spares: Reliance MaxPak Plus, GV3000/6000 DC bus sections.

  • Heavy Industry: Mining, steel, paper, cement plants.

Compatible Drives

  • Reliance MaxPak Plus DC Drives

  • Reliance GV3000 / GV6000 (DC bus assemblies)

  • ABB/Baldor‑Reliance 460V DC drive systems

Installation & Maintenance

Mounting

  • Vertical only; 100 mm clearance above heat sinks.

  • Torque mounting bolts to 4.5 Nm; ensure good chassis ground.

Wiring

  • AC Input: L1, L2, L3 (460V 3‑phase)

  • DC Output: +DC, −DC (to armature/load)

  • Gate Signals: To/from drive control board via 0‑51378‑19 cables.

Maintenance

  • Clean heat sinks quarterly (compressed air).

  • Check gate board connections annually (1.2 Nm torque).

  • Test SCR leakage every 2 years; replace if >5 mA at full voltage.