0-864660-59S
May 27, 2026

0-864660-59S

Model: 0-864660-59S (also 86466-59S) Manufacturer: Reliance Electric (ABB/Baldor-Reliance) Type: 3‑Phase Thyristor Rectifier Stack (SCR Power Module) Series: MaxPak Plus / Drive Rectifier Assemblies Overview: Heavy‑duty 460V AC‑to‑DC rectifier stack for industrial DC drives, motor controls, and high‑power conversion; uses press‑pack thyristors and dual heat sinks.

Description

Technical Specifications

  • Part Number: 0-864660-59S (86466-59S)

  • Input Voltage: 3‑phase 460 VAC (380–480 VAC range)

  • Frequency: 50 / 60 Hz

  • Output: Full‑wave bridge DC

  • Thyristor Type: Press‑pack (high‑current)

  • Heat Sinks: Dual finned aluminum, bolted to central carrier

  • Gate Cards: Two 0‑51378‑19 coupling boards (transformer, resistors, diodes)

  • Protection: Metal oxide varistors (MOVs), RC snubbers

  • Mounting: Chassis‑mount, vertical orientation

  • Weight: ~22.7 kg (50 lbs)

  • Dimensions (approx): 350 × 200 × 150 mm

  • Insulation: Class F (155°C)

Key Features

  • High Power Conversion: Designed for 460V industrial systems, ideal for heavy loads.

  • Robust SCR Design: Press‑pack thyristors for high current and long life.

  • Integrated Protection: MOVs and RC snubbers suppress voltage spikes and noise.

  • Dual Heat Sinks: Efficient cooling for continuous high‑power operation.

  • Gate Coupling Boards: Pre‑wired 0‑51378‑19 cards simplify drive integration.

  • Drop‑In Replacement: Interchangeable with 86466‑58S / 60S in MaxPak Plus series.

Applications

  • DC Motor Drives: For large conveyors, cranes, extruders, and rolling mills.

  • Industrial Power Supplies: High‑current DC for plating, electrolysis, and heating.

  • Retrofits & Replacements: Upgrade or repair existing Reliance MaxPak Plus systems.

  • Heavy Machinery: Mining, steel, paper, and cement plant equipment.

Compatible Drives & Controllers

  • Reliance MaxPak Plus DC Drives

  • Reliance GV3000 / GV6000 (DC bus sections)

  • ABB / Baldor‑Reliance 460V DC drive systems

Installation & Maintenance Notes

Mounting

  • Vertical mounting only; allow 100 mm clearance above heat sinks for airflow.

  • Torque mounting bolts to 4.5 Nm; ensure chassis ground connection.

Wiring

  • AC Input: L1, L2, L3 (460V 3‑phase)

  • DC Output: +DC, −DC (to armature/load)

  • Gate Signals: To/from drive control board via 0‑51378‑19 cables.

Maintenance

  • Inspect heat sinks quarterly for dust buildup; clean with compressed air.

  • Check gate card connections annually; tighten terminals to 1.2 Nm.

  • Test thyristor leakage every 2 years; replace if >5 mA at full voltage.


Get a Quote