0-86428-B
May 27, 2026

0-86428-B

Model: 0-86428-B (Baldor / ABB DC Servo Motor) Manufacturer: Baldor (ABB) Series: 086428-B / E660 family (NEMA 34, 90VDC brushed DC servo) Overview: Medium–high power brushed DC servo motor for industrial closed‑loop positioning; compatible with 0846181xR series but different winding/feedback.

Description

Technical Specifications

  • Model: 0-86428-B

  • Type: Brushed DC Servo (Permanent Magnet)

  • Frame: NEMA 34 (86 mm square)

  • Rated Voltage: 90 VDC

  • Rated Power: 1.1 kW

  • Continuous Torque: 4.2 Nm

  • Peak Torque: 12.6 Nm (3× overload)

  • Rated Speed: 2500 RPM

  • Max Speed: 4000 RPM

  • Rated Current: 6.5 A

  • Peak Current: 19.5 A

  • Encoder: 500 PPR differential A/B/Z, 5 VDC

  • Shaft: 5/8" (15.88 mm) with keyway

  • Protection: IP44 (shaft IP54)

  • Insulation: Class F (155°C)

  • Weight: ~7.8 kg

Key Features

  • High Torque Density: 4.2 Nm continuous in NEMA 34 frame.

  • Precision Feedback: 500 PPR differential encoder for noise immunity.

  • High Inertia Rotor: Matches high‑inertia loads, smooth motion (no cogging).

  • Industrial Grade: IP44, Class F insulation, long‑life servo bearings.

  • Easy Integration: Directly compatible with Baldor DC1/DC‑35 drives.

Applications

  • CNC routing/engraving machines

  • Medium‑duty packaging & labeling lines

  • Pick‑and‑place & assembly stations

  • High‑inertia rotary tables & indexers

  • Retrofit/replacement for 08461813R / 08461815R

Compatible Drives

  • Baldor DC1, DC‑35 (90 VDC, 8 A continuous)

  • Other 90 VDC industrial DC servo drives

Operating Instructions (Summary)

Mounting

  • NEMA 34 flange: 4×M5 bolts, torque to 2.5 Nm.

  • Coupling coaxiality ≤ 0.08 mm; avoid radial loads.

  • Power cable ≥16 AWG; encoder: shielded twisted pair, ≤10 m.

Wiring

  • Power: A+ (armature +), A− (armature −), FG (ground)

  • Encoder: +5V, GND, A±, B±, Z±

Commissioning

  • Drive setup: DC Servo, 90 VDC, 6.5 A, 500 PPR.

  • No‑load jog at 500 RPM; check rotation, noise, encoder signal.

  • Gradually apply load; monitor winding temperature (<155°C).

Maintenance

  • Brushes: Inspect every 2000 hours; replace if <5 mm length.

  • Bearings: Regrease every 4000 hours (Mobil XHP 222).

  • Insulation test: Annually, armature‑to‑ground ≥1 MΩ (500 VDC).


Get a Quote