08461815R
Description
II. Technical Specifications
Model: 08461815R (0-846181-5R)
Series: E660 Permanent Magnet Brushed DC Servo
Flange: NEMA 34 (86mm square)
Rated Voltage: 90 VDC
Rated Power: Approximately 1.2 kW
Rated Torque: 4.5 Nm (Continuous)
Peak Torque: 13.5 Nm (3 times)
Rated Speed: 2500 RPM
Maximum Speed: 4000 RPM
Rated Current: 6.8 A
Peak Current: 20.4 A
Encoder: 500 PPR Differential A/B/Z, 5V
Shaft Diameter / Groove: 5/8" (15.88 mm)
Protection: IP44 (Axial End IP54)
Insulation: F Class (155℃)
Weight: Approximately 8.2 kg
III. Core Functions
Higher Continuous Torque: 4.5 Nm, suitable for medium and heavy loads, high inertia loads
Closed-loop High Precision: 500 PPR Differential Encoder, strong anti-interference, accurate positioning
Wide Speed Range Stability: 2500 RPM rated, 4000 RPM maximum, large speed adjustment range
Industrial-grade Protection and Insulation: IP44 + F Class Insulation, strong environmental adaptability
Long Life and Easy Maintenance: Standard brush / bearing design, simple replacement, low cost
IV. Applicable Scenarios
Industrial Automation: Heavy-duty CNC, packaging / printing main line, injection molding machine servo axis
Precise Positioning: Large displacement table, machine main feed, automated mechanical hand
Equipment Upgrade: Replace E660 Series 08461811R / 08461813R to enhance load capacity
Compatible Drives: Baldor DC1, DC-35, etc. 90VDC DC Servo Drives
V. Usage Instructions
1. Installation
Flange Fixation: NEMA 34 4×M5 Bolts, Torque 2.5 Nm
Alignment: ≤0.08 mm, avoid radial load
Cables: Power Cable ≥14AWG, Encoder Twisted Shielded Cable, Length ≤10 m
2. Wiring
Power: A+ (Armature +), A- (Armature -), FG (Ground)
Encoder: +5V, GND, A±, B±, Z±
3. Debugging
Driver Parameters: DC Servo, 90VDC, 6.8A, 500PPR
No-load Point Movement: 500 RPM, check direction, abnormal noise, encoder feedback
Step-by-step Loading: to rated torque, observe temperature rise and stability
4. Maintenance
Brush: Check every 2000 hours, replace when worn to 5mm
Bearings: Add high-temperature lubricating grease every 4000 hours (Mobil XHP 222)
Insulation: Test once a year, Armature to Ground ≥1 MΩ (500VDC Multimeter)
Get a Quote