0-57409-B
Description
Part Number Definition
0-57409-B
0-57409: Base AutoMax 2-channel isolated analog input module
B: Revision B (PCB & firmware update, improved isolation/noise immunity)
Full name: Isolated Control A/D Analog Input Module for AutoMax / DCS 5000
Compatibility: Drop-in compatible with 0-57409 / -C; works with 0-57407 CPU series and standard AutoMax racks/power supplies.
Technical Specifications
Manufacturer: Reliance Electric (now Rockwell Automation)
Function: Converts 2 channels of isolated analog signals (voltage/current) to digital values for the AutoMax DCS/PLC.
Inputs: 2 isolated analog channels, differential
Signal Ranges (per channel, software-selectable):
Voltage: ±10 VDC, ±5 VDC, 0–10 VDC, 0–5 VDC
Current: 4–20 mA (external 250 Ω resistor required)
Resolution: 12-bit A/D converter
Isolation: 2500 VAC channel-to-channel and channel-to-backplane
Operating Voltage: 15 VDC (from AutoMax backplane)
Operating Temperature: 0°C to +60°C
Dimensions: 342 × 205 × 30 mm (1.25” slot)
Weight: Approx. 0.7–0.9 kg
Protection: IP20; no conformal coating (Rev B)
Power Consumption: ≤ 12 W
Front Panel & Indicators
No LEDs or display; edge connector to backplane, field wiring via front terminal block (not included).
Supports hot-swap installation/removal.
Key Features
2 fully isolated analog inputs for noise rejection in harsh industrial environments.
Software-configurable voltage/current ranges for flexible sensor interfacing.
12-bit high-resolution conversion for accurate process monitoring.
Standard AutoMax backplane form factor, no adapter needed.
Revision B improvements:
Enhanced PCB layout for lower crosstalk
Firmware calibration stability updates
Improved isolation barrier integrity
Revision Notes (0-57409 Series)
0-57409: Original release (Rev A)
0-57409-B: Revision B (performance & noise immunity upgrade)
0-57409-C: Revision C (conformal coating, extended temp range -10°C to +60°C)
Applications
System: Reliance AutoMax / DCS 5000
Industries: Process control, manufacturing, power generation, pulp & paper, water treatment
Use: Monitoring analog sensors (pressure, temperature, flow, level) in multi-motor or distributed control systems.
Installation & Maintenance
Insert into an empty AutoMax backplane slot, secure latches, wire field signals to the terminal block.
Quarterly: Check wiring tightness and connector integrity.
Biannually: ESD-safe cleaning of connectors and front panel.
Interchangeable with all 0-57409 revisions; no program changes required.
Get a Quote