0-54390
Description
Model Definition
0-54390: Base part number (PC Power Supply Board)
Status: Discontinued by manufacturer; no direct OEM replacement
Cross-Reference: No fully compatible equivalent; replacement requires exact part match or system reconfiguration
Technical Specifications
Form Factor: Standard 3U PCB (approx. 248 × 171 mm)
Weight: ~0.6 kg
Input Voltage: 115/230 VAC, 50/60 Hz
Output Voltages: ±15 VDC (1 A), +5 VDC (3 A), +24 VDC (2 A)
Regulation: ±0.5% for all outputs
Protection: Overvoltage, overcurrent, short-circuit protection
Components: Switching regulator, transformers, capacitors, fuses, status LEDs
Operating Temp: 0 °C to +55 °C
Mounting: 3U rack slot, edge connector (AutoMax/MaxPak backplane)
Interfaces & Communication
Backplane: 3U goldfinger edge connector (fits AutoMax/MaxPak rack)
AC Input: Screw terminals for 115/230 VAC power
DC Outputs: Hardwired to backplane for system distribution
No Network Ports: Hardwired power supply; no serial/Ethernet communication
Key Features
Multi-Voltage Output: Provides ±15 VDC, +5 VDC, and +24 VDC for drive logic and I/O
Overload Protection: Built-in fuses and electronic protection against short circuits
LED Status Indicators: On-board LEDs for AC power, DC output, and fault status
High Efficiency: Switching regulator design reduces heat generation
3U Rack Mount: Seamless integration into existing AutoMax/MaxPak drive cabinets
Application
Drive Systems: AutoMax DC Drives, MaxPak Series DC Drives (50–2000 HP)
Subassemblies: Control racks, logic cabinets, auxiliary control panels
Industries: Steel, paper, mining, cranes, conveyors, machine tools
Function: Primary power supply for control and interface circuitry in DC drive systems
Compatibility
Compatible Racks: AutoMax DCS Rack, MaxPak Drive Rack
Voltage Compatibility: 230/460/575 VAC DC drives
Power Range: 50–2000 HP (matches AutoMax/MaxPak drive ratings)
Critical Notes
Function Distinction: Separate from 0-54374 (relay board), 0-54379-1 (auxiliary “M” kit); this is the main system power supply
Replacement Challenge: No direct substitute; refurbished units are the most common solution
Availability: Limited stock; longer lead times; pricing varies by condition and supplier
Get a Quote