JANCD-I0O2
May 25, 2026

JANCD-I0O2

Brand: YASKAWA (Yasuna) Series: LX3 / LX Series CNC/PLC General I/O Board Material Number: JANCD-IO02 (without suffix) Purpose: Standard digital I/O expansion board for Yasnac LX3 CNC system / PLC, used in machine tools and specialized automation equipment.

Description

I. Product Introduction

1. Positioning

Basic type 40 input / 40 output digital I/O board, included in the LX3 system / commonly used expansion.

Used for CNC machines, special machinery, and small production lines, connecting sensors, buttons, solenoid valves, contactors, etc.

2. Core Specifications

Input: 40 points DC24V (NPN, low level valid)

Output: 40 points transistor DC24V, 0.3A / point

Interface: 2×50-pin flat cable sockets (CN1, CN2)

Power Supply: Backplane DC5V + external DC24V (≥2A)

Size: Approximately 310×215 mm (standard JANCD large board)

Temperature: 0℃~45℃, no condensation

Humidity: 10%~90% RH, no condensation

Version: Common Rev B1/B2

3. Main Functions

✅ 40 input + 40 output universal I/O, meeting the signal point requirements of small and medium-sized equipment

✅ LED status indication: Each I/O has an LED, facilitating on-site line inspection

✅ System bus communication: High-speed data interaction with LX3 main control board

✅ Short-circuit protection: Output end with self-recovery fuse, anti-surge

II. User Manual (Key Points)

1. Installation (LX3 Control Cabinet)

Slot: LX3 dedicated I/O slot (SLOT02/SLOT03, default front slot)

Fixation: 4 M3 screws, torque 0.8~1.0 N·m

Compatibility: Only Yasnac LX3/LX systems; cannot be used in XRC robot cabinets, DX series, or other brand CNC.

2. Wiring (CN1/CN2)

CN1 (50-pin): Input IN0~IN39

Common terminal: COM1 (24V+)

Signal: NPN sensor / switch negative pole → INx (low level valid)

CN2 (50-pin): Output OUT0~OUT39

Common terminal: COM2 (0V)

Load: Positive pole connected to 24V+, negative pole → OUTx

⚠️ Output limit: Single path ≤ 0.3A, entire board ≤ 2A;严禁 overload / short circuit.

3. I/O Address (LX3 System)

Input: IN0~IN39 → Address X000~X039

Output: OUT0~OUT39 → Address Y000~Y039

View: LX3 programmer → Diagnosis → I/O status

4. Fault Diagnosis

No indicator light for input: Check DC24V, COM1 wiring, sensor polarity

Output does not act: Check load wiring, COM2 connected to 0V, program ladder diagram

Communication error: Clean gold fingers, change slot, check backplane bus


Get a Quote