JANCD-I020
Description
I. Product Introduction
1. Core Positioning
High-density I/O expansion board, specially designed for Yasnac LX3 CNC/PLC.
Used for machine tools and large-scale automated production lines, handling a large number of digital signals such as sensors, solenoid valves, safety circuits, PLC interlocks, etc.
2. Key Specifications (I020-03)
Input Points: 112 points (DC24V, NPN/PNP compatible)
Output Points: 64 points (transistors, DC24V, 0.5A per point)
Interfaces: Multiple groups of 50-pin flat cable sockets (CN1 to CNx)
Power Supply: Backplane DC5V + external DC24V (≥3A)
Temperature: 0℃ to 45℃ (no condensation)
Humidity: 10% to 90% RH (no condensation)
Vibration: ≤0.5G
Weight: Approximately 0.71 kg
3. Main Functions
✅ Massive I/O Expansion: 112 inputs + 64 outputs, meeting the point requirements of large equipment.
✅ Safety Signal Processing: Emergency stop, safety door, limit switch, etc., hard logic monitoring.
✅ Peripheral Integration: Machine tool sensors, fixtures, cooling / lubrication system control.
✅ Status Diagnosis: On-board LED indicators, real-time display of each I/O status.
✅ System Bus Communication: High-speed data interaction with LX3 main control board.
II. User Manual (Core Points)
1. Installation (LX3 Control Cabinet)
Slot: LX3 dedicated I/O expansion slot (such as SLOT04/SLOT05).
Fixation: 4 M3 screws, tightening torque 0.8 to 1.0 N·m.
Compatibility: Only compatible with Yasnac LX3 system, cannot be used in XRC/ERC robot cabinets or DX series.
2. Wiring Specifications
Input (IN0 to IN111):
Common terminal: COM+ (24V)
Signal terminal: Connect NPN sensors / switches negative pole (low level valid).
Output (OUT0 to OUT63):
Common terminal: COM- (0V)
Signal terminal: Connect load negative pole, load positive pole connects to 24V+.
⚠️ Output Limitation: Single path ≤0.5A, total board current ≤3A,严禁 overload.
3. I/O Address Allocation (LX3 System)
General Input: IN0 to IN111 → Address X000 to X111
General Output: OUT0 to OUT63 → Address Y000 to Y063
View / Force: LX3 programmer → Input / Output → Expansion I/O.
4. Fault Troubleshooting
Input no response: Check DC24V power supply, COM terminal wiring, sensor polarity.
Output does not act: Confirm load wiring, COM- terminal connects to 0V, program logic / ladder diagram.
Communication error: Check board card gold fingers, backplane slot, system firmware version match.
Get a Quote