JANCD-IO02
Description
I. Core Function
Machine tool operation panel button / indicator light signal processing
M/S/T auxiliary function output (cooling, lubrication, spindle, tool magazine)
Emergency stop, limit, door lock and other safety signal collection
CNC and machine strong power cabinet signal conversion and isolation
With relay drive, can directly control contactors / solenoid valves
II. Specification Highlights
Board size: Standard JANCD large board (approximately 310×215 mm)
Version: Common REV A/B
Interfaces: CN1 to CN4 multiple groups of 20/50-pin flat cable sockets
Signal levels: DC24V input / output, with LED status lights
Power supply: Backplane DC5V + external DC24V
Power consumption: Approximately 15W
Weight: Approximately 0.8 kg
III. Differences from Similar Models
JANCD‑IO02: CNC machine I/O (Senkei Machine)
JANCD‑I0 (IO): Another CNC I/O (Matsuura)
JANCD‑AIO01/02: Robot control cabinet I/O (XRC/FS100)
IV. Common Faults and Replacement
Typical faults: Panel no response, M code not executed, cooling / lubrication not actuated, indicator lights not lit
Replacement points:
Priority DE8100285, REV A/B
Must match the wiring definition on the machine side and the system ladder diagram
Cannot be replaced with the robot JANCD‑AIO series