JANCD-I0
Description
I. Core Functions
Signal processing of the machine tool operation panel (buttons, indicator lights, knobs)
M/S/T auxiliary functions I/O (cooling, lubrication, spindle, tool magazine)
Collection and output of external interlock / emergency stop / limit signal
CNC and machine side electrical interface conversion
Relay / contactor drive output (with insurance)
II. Specification Highlights
Board shape: Standard JANCD large board (approximately 310×215mm)
Interfaces: Multiple groups of 50-pin / 20-pin flat cable sockets (CN1–CN4)
Signals: DC24V I/O, with LED status indication
Power supply: Backplane DC5V + external DC24V
Environment: 0°C – 55°C, no condensation
Weight: Approximately 0.8kg
III. Common Confusing Models
JANCD-I0: CNC machine I/O (OIB, Matsuda, etc.)
JANCD-IO01: Robot XRC control cabinet I/O
JANCD-YIO21: Robot DX200 control cabinet I/O
JANCD-AIO01: Robot YRC1000 control cabinet I/O
IV. Faults and Replacement
Typical faults: Panel no response, M code not executed, cooling / lubrication out of control, indicator light abnormal
Replacement: Prefer REV A, material number DF8000020; need to match the wiring definition on the machine side