Description
I. Product Overview
Model: JANCD-GCP02 (Material Number: DE6428363, Version: Rev A)
Category: CNC Core CPU Motherboard
Applicable: YASNAC DTN-1990 / 2000G CNC system (for early high-end machine tool controllers)
Function Positioning: System calculation, program parsing, axis control, I/O management, communication coordination
II. Core Functions
Main Control Calculation: Central part of the CNC system, executing G codes / M codes, interpolation calculation, trajectory planning
Axis Control Management: Multi-axis linkage control, servo parameter calculation, position closed-loop control
Program Storage and Execution: Loading and running part programs, macro programs, system parameters
I/O and Communication: Coordinating panel, handwheel, external I/O, RS232 and other interface signals
System Diagnosis: Power-on self-check, operation monitoring, fault code generation
III. Technical Parameters
Structure: Full-size long card (approx. 330×140mm), gold finger slots
Processor: Special 16/32-bit CNC processor, main frequency approximately 8–16MHz
Memory: On-board RAM/ROM (including system firmware and user program area)
Interfaces: Special system bus, I/O bus, panel / handwheel interface, communication ports
Power Supply: Backplane DC5V/±12V, power consumption approximately 25W
Temperature: Working 0–55℃, storage -20–70℃
Weight: Approximately 1.3kg
IV. Installation and Maintenance
Installation: Insert vertically into the CPU main slot (leftmost long slot on the frame), lock and fix the screws; leave 50mm space for heat dissipation
Maintenance: Regularly blow dust off the board; check for oxidation / burn damage of gold fingers; back up system parameters and processing programs
V. Common Faults
No response / black screen upon startup: CPU core damage, crystal oscillator failure, power supply circuit fault
System reports "CPU ERROR": Board damage or poor contact
Abnormal program execution / system freeze: Aging memory chips, failure of calculation unit
Axis control abnormality / large following error: Axis control module failure, unstable bus communication