JANCD-FC903
Description
1. General Description
2. Basic Specifications
Compatible System: YASNAC I80 / I80M (all variants)
Backplane: JANCD-FC001 (1 full slot)
Dimensions: 216 × 140 mm
Panel Interface: 50-pin ribbon cable connector (to operator panel)
Bus Interface: Internal I80 system bus (to FC500 PLC core)
Operating Current: ~0.3 A (24 V DC)
Operating Temperature: 0 °C to +60 °C
Storage Temperature: −20 °C to +70 °C
Humidity: ≤80% RH (non-condensing)
3. Key Features
Panel Signal Processing
Connects to operator panel keys, mode switches, cycle start/stop buttons
Drives panel LEDs (power, alarm, cycle status, axis indicators)
Converts panel switch inputs to CNC-compatible logic signals
Integrated Circuit Design
On-board signal conditioning and ESD protection for panel I/O
Direct connection to FC500 PLC core via internal bus
No external wiring needed for panel-CNC communication
Compatibility & Reliability
Matches YASNAC I80 standard operator panels
Supports Hitachi Seiki machine retrofits (OEM compatibility)
Compact design with surface-mount components for stability
4. Compatibility & Configuration
Required Boards
CPU: JANCD-FC250 / FC251
PLC Core: JANCD-FC500 (mandatory)
Backplane: JANCD-FC001
Typical System Setup
Standard I80: FC251 + FC500 + FC903 + FC860 (display board)
Hitachi Seiki retrofit: FC250 + FC500 + FC903-1B
Limitations
Max 1 board per system
Dedicated to operator panel I/O (cannot be used for general I/O)
5. Common Faults
Panel keys unresponsive: Ribbon cable loose or connector damage
LED indicators not lighting: On-board driver chip failure
Intermittent panel communication: Backplane contact issue
No panel power: 24 V DC input fuse blow
6. Applications
YASNAC I80 CNC machine tools (lathes, mills, machining centers)
Hitachi Seiki machine retrofits (OEM replacement)
Systems requiring dedicated operator panel-CNC interface
Replacement for aging FC903 boards in legacy I80 installations