JANCD-FC900C
May 25, 2026

JANCD-FC900C

JANCD-FC900C Brand: Yaskawa / Yasnac Model: JANCD-FC900C (Sub: -1) Part No: DF9200271-A0 (Rev A02) Type: High-Speed Serial Communication Board (YASNAC I80 Series) Weight: Approx. 0.16 kg (0.35 lbs)

Description

1. General Description

JANCD-FC900C is a compact, high-speed serial communication board for the YASNAC I80 CNC system, serving as an upgraded, smaller form-factor alternative to the FC900B. It enables reliable data exchange with external devices (host, HMI, DNC) while occupying minimal slot space, optimized for cost-sensitive and space-constrained I80 configurations.

2. Basic Specifications

  • Compatible System: YASNAC I80 / I80M

  • Backplane: JANCD-FC001 (1 full slot)

  • Dimensions: 216 × 140 mm (smaller than FC900B)

  • Communication Ports: 2 × RS-232/RS-422 selectable

  • Baud Rate: Up to 115.2 kbps

  • Protocols: Xmodem, Ymodem, DNC, Yaskawa proprietary

  • Operating Current: ~0.25 A (24 V DC)

  • Operating Temperature: 0 °C to +60 °C

  • Storage Temperature: −20 °C to +70 °C

  • Humidity: ≤80% RH (non-condensing)

  • Protection: ESD/surge protection, LED status indicators

3. Key Features

Compact & Cost-Effective

  • 35% smaller than FC900B, ideal for slim I80 setups

  • Lower power consumption, reducing system load

Dual-Port Communication

  • Two independent ports for simultaneous connection to DNC + HMI

  • Hardware-driven transfer, no CPU performance impact

Protocol Versatility

  • Supports standard DNC for online machining

  • Compatible with Yaskawa HMIs and third-party controllers

  • Switchable RS-232 (point-to-point) / RS-422 (multi-drop)

4. Compatibility & Configuration

Required Boards

  • CPU: JANCD-FC250 / FC251

  • PLC Core: JANCD-FC500

  • Backplane: JANCD-FC001

Typical System Setup

  • Compact DNC: FC250 + FC500 + FC900C + FC810

  • HMI Link: FC251 + FC500 + FC900C

Limitations

  • Max 1 board per system

  • Occupies one full slot on FC001 backplane

5. Common Faults

  • Communication timeout: Cable fault, baud rate mismatch

  • Port failure: ESD damage or driver chip burnout

  • Bus error: Backplane contact issue

  • No power: 24 V loss or internal fuse blow

6. Applications

  • Compact 3–5 axis CNC machines (lathes/mills)

  • Cost-sensitive I80 system upgrades

  • DNC-connected production lines

  • Machines requiring HMI + external controller links


Get a Quote