JANCD-FC860
May 25, 2026

JANCD-FC860

JANCD-FC860 Brand: Yaskawa / Yasnac Model: JANCD-FC860 Part No: DF9201376-A0 Type: High-Density Digital I/O Board (YASNAC I80 Series) Weight: Approx. 0.54 kg (1.2 lbs)

Description

1. General Description

JANCD-FC860 is a high-density digital input/output board designed for the YASNAC I80 CNC system. It provides large-scale I/O expansion for complex machine tools and automated lines, connecting to the FC500 PLC core board via the internal high-speed bus. It is functionally equivalent to FC810 but with updated circuit design and terminal layout.

2. Basic Specifications

  • Compatible System: YASNAC I80 / I80M (Turn/Mill)

  • Backplane: JANCD-FC001 (occupies 1 full slot)

  • Dimensions: 267 × 140 mm

  • I/O Points: 112 inputs / 96 outputs

  • Input Voltage: DC 24 V ±10% (sink/source selectable)

  • Output Rating: DC 24 V, 0.5 A per point (short-circuit protected)

  • Operating Current: ~0.5 A (24 V DC)

  • Operating Temperature: 0 °C to +60 °C

  • Storage Temperature: −20 °C to +70 °C

  • Humidity: ≤80% RH (non-condensing)

  • Protection: Surge protection on all I/O lines, LED status indicators

3. Key Features

High-Density I/O

  • 112 universal 24 V DC inputs (NPN/PNP compatible)

  • 96 transistor outputs with overcurrent and short-circuit protection

  • Flat-type connector design for reliable wiring (YENET interface)

System Integration

  • High-speed bus connection to FC500 PLC board

  • Real-time I/O data refresh for fast control response

  • Compatible with FC510 (memory) and FC520 (communication) boards

Industrial-Grade Reliability

  • Six-layer FR4 PCB for noise immunity

  • LED indicators for power, bus communication, and I/O status

  • Panel-mount design with screw terminals for stable connection

4. Compatibility & Configuration

Required Boards

  • CPU: JANCD-FC250 / FC251

  • PLC Core: JANCD-FC500 (mandatory)

  • Backplane: JANCD-FC001 (min. 3 slots)

Typical System Setup

  • 6-axis machining center: FC251 + FC500 + FC860 + FC630

  • Multi-station automation line: FC250 + FC500 + FC860 + FC440

Limitations

  • Max 4 boards per system (total 448 inputs / 384 outputs)

  • Occupies one full slot on the FC001 backplane

5. Common Faults

  • I/O communication error: Loose backplane connection or bus fault

  • Input no response: Wiring failure or internal channel damage

  • Output failure: Load short circuit or drive transistor burnout

  • All LEDs off: 24 V power loss or blown internal fuse

6. Applications

  • Multi-axis CNC machine tools (5–6 axis)

  • Automated production lines with multiple workstations

  • Machine tools with extensive auxiliary functions (coolant, lubrication, ATC)

  • I80 system upgrades for increased PLC I/O capacity