JANCD-FC800
Description
1. General Description
2. Basic Specifications
Compatible System: YASNAC I80 / I80M (Turn/Mill)
Backplane: JANCD-FC001 (1 full slot)
Dimensions: 267 × 140 mm (standard FC-series form factor)
I/O Points: 112 inputs / 96 outputs (total 208 points)
Output Voltage: DC 24 V ±10%
Operating Current: ~0.5 A (24 V DC)
Operating Temperature: 0 °C to +60 °C
Storage Temperature: −20 °C to +70 °C
Humidity: Up to 80% RH (non-condensing)
Altitude: Up to 1,000 m above sea level
3. Key Features
A. High-Density I/O
112 discrete inputs (24 V DC, sink/source selectable)
96 discrete outputs (24 V DC, 0.5 A per point, short-circuit protected)
200% terminal block support (accommodates extensive wiring)
B. System Integration
CN61 high-speed bus to FC500 (10 Mbps)
Dual socket design for expanded connectivity
Full compatibility with FC500/FC510/FC520 and FC6xx motion boards
C. Industrial Reliability
Surge protection on all I/O lines
LED status indicators for power, bus, and I/O activity
Compact, durable PCB (FR4 material, six-layer design)
4. System Configuration
Mandatory Boards
CPU: FC250 / FC251
PLC Core: FC500 (required)
Backplane: FC001 (min. 3 full slots)
Typical Setup
High-I/O machining center: FC251 + FC500 + FC800 + FC620 (motion)
Multi-station automation lathe: FC250 + FC500 + FC800 ×1 + FC430 (128 I/O)
Limitations
Max 2 × FC800 per system (total 416 I/O points)
Occupies 1 full slot; cannot coexist with some FC4xx I/O boards
5. Common Faults & Alarms
I/O Bus Error: CN61 loose connection, FC500 communication fault
Output Short Circuit: Overloaded output point, damaged transistor array
Input Signal Drift: 24 V power supply instability, loose wiring
No LED: 24 V power loss, internal fuse blown, backplane contact issue
6. Applications
High-I/O CNC machines (5–6-axis, multiple peripherals)
Multi-station automated production lines (3+ workstations)
Machine tools with extensive auxiliary functions (coolant, lubrication, tool changers)
I80 system upgrades for increased PLC I/O capacity