jancd-fc440
Description
1. General Description
2. Basic Specifications
Applicable system: YASNAC I80 / I80M (requires FC251 CPU board exclusively)
Backplane: JANCD‑FC001 (1 full slot)
Board size: Full‑length (≈267 × 140 mm)
Power supply: DC 24V ±10%, approx. 2.0 A
Operating temperature: 0 to +45°C
Storage temperature: −20 to +60°C
3. I/O Configuration (Max‑Density)
Inputs (IN): 160 points
Signal level: DC 24V, sink/source selectable (NPN/PNP compatible)
Usage: Limit switches, proximity sensors, E‑stop, safety doors, tool sensors, clamps, pallets, fixture sensors
Response time: ≤0.8 ms (high‑speed sampling)
Outputs (OUT): 160 points (transistor)
Voltage: DC 24V, max 0.5 A per point
Usage: Solenoids, relays, valve banks, indicators, alarms, cylinders, motor start signals
Protection: Self‑resetting fuse per point, overload/short‑circuit protection, surge suppression
Connectors
CN44: I/O terminal block (160IN / 160OUT, screw terminals, 4 rows)
CN20: System bus (high‑speed link to FC251)
LEDs: Power, bus status, IN/OUT channel status, fault diagnostics
4. FC440 vs FC430 vs FC420 vs FC410 vs FC400
| Item | FC440 (Max‑Density) | FC430 (Ultra‑High) | FC420 (High‑Density) | FC410 (Expansion) | FC400 (Standard) |
|---|---|---|---|---|---|
| I/O points | 160IN/160OUT | 128IN/128OUT | 96IN/96OUT | 64IN/64OUT | 32IN/32OUT |
| Board size | Full‑length | Full‑length | Full‑length | Full‑length | Half‑length |
| Max per system | 1 board | 1 board | 1 board | 2 boards | 2 boards |
| I80 I/O limit | 320 total | 256 total | 192 total | 128 total | 64 total |
| Typical use | 6‑axis, auto lines, cells | 5‑axis, large machines | Mid‑large machines | Mid‑size machines | Standard lathes |
5. System Compatibility & Combinations
Mandatory pairing
CPU board: JANCD‑FC251 (high‑grade) (FC250 not supported)
Backplane: JANCD‑FC001
Recommended configurations
Max‑density setup: FC251 + 1×FC440 (320 I/O total, I80 maximum)
Mixed high‑density setup: FC251 + FC440 + FC400 (384 I/O total)
Axis boards: FC260 (8‑axis feed), FC310 (spindle)
Limitations
Cannot be used standalone (depends on FC251 for power and bus)
Occupies 1 full slot on FC001 backplane
I80 system limit: 1×FC440 maximum (full bus bandwidth utilization)
6. Common Faults & Alarms
A.440 Bus error: CN20 loose, backplane contact failure, bus chip overload
No input signals: CN44 wiring loose, 24V supply fault, input channel burnout
Outputs not activating: Overload/short circuit, load fault, wiring error, surge damage
All LEDs off: Backplane 24V missing, internal main fuse blown
Partial channel failure: Terminal block oxidation, bent pins, internal trace damage
7. Applications
Large 6‑axis machining centers (max I/O for clamps, pallets, tools, safety interlocks)
Multi‑station transfer lines (high sensor/actuator count for synchronized motion)
Fully automated production cells (machine + material handling + inspection + robotics)
High‑end multi‑spindle turn‑mill centers (dual spindle + multiple turrets + B/C axes)
Legacy system upgrades (max I/O expansion without full CNC replacement for large machines)