JANCD-FC240
Description
I. Basic Information
Material Number: DF8203860-D0
Compatible System: YASNAC I80 / I80M Full Series CNC (Requires FC230B for use)
Assembly Backplate: JANCD-FC001 (Standard Backplate for I80)
Board Card Size: 267 × 152 mm (General Size for I80)
Weight: Approximately 0.29 kg
Power Supply: DC 5V ±5%, approximately 1.2 A (Backplate Power Supply, Power Consumption ≈ 6W)
Operating Temperature: 0°C ~ +55°C
Version: No derivative version, FC240 is the only model
II. Core Functions
Multi-axis Data Distribution (Core)
As an extension of FC230B (Motion Management Board), it shares high-speed data traffic
Manage 8-axis servo + 2-axis spindle command / feedback data routing
Reduce the load of FC230B and improve the overall system response speed
High-speed Bus Expansion
Provide an additional 2 channels of high-speed servo bus interfaces (CN28/CN29)
Support expansion of I80 system axis count to 16 axes (Requires multiple FC240s cascaded)
Bus Rate: 100 Mbps, Strong Anti-interference Capability
Signal Conversion and Isolation
Servo / Spindle Signal Photoelectric Isolation, Protecting Core Board Card
Differential Signal to Single-ended Signal, Adapted to Different Drive Interfaces
Filter Circuit Design, Reducing EMI/RFI Interference
System Monitoring and Alarm
On-board 4-channel LED Status Lights, Real-time Display: Power, Bus, Data, Fault
Monitor Data Transmission Errors, Bus Timeout, Signal Abnormalities
Fault Code Upload to CPU Board (FC200), Facilitating Diagnosis
Expansion Interface Support
CN28: Servo Expansion Interface (4 Axes)
CN29: Spindle Expansion Interface (2 Axes)
CN30: High-speed Data Interface with FC230B
III. Compatibility and Pairing
✅ Required Board Cards (I80 Expansion Configuration)
CPU Board: JANCD-FC200 (SMON Main Control Board)
Motion Management Board: JANCD-FC230B (MMON, Core)
Data Distribution Board: JANCD-FC240 (DDB, Extension)
Servo Interface Board: JANCD-FC226 (Signal Conversion)
PLC Board: JANCD-FC210 / FC211
✅ Replacement and Expansion Rules
Cannot be used alone: Must be paired with FC230B, without FC230B, FC240 cannot work
Cascading Expansion: The I80 system can support up to 2 FC240s, expanding to 16 axes
Incompatible with Old Systems: Only for I80/I80M, does not support I60/C70
No Alternative Models: FC240 is the exclusive expansion board for I80, no compatible alternative models
IV. Common Fault Phenomena
System Reports "Servo Bus Error" → FC240 Bus Interface Damaged or Data Link Fault
Some Servo Axes Disappear / Intermittent → Poor Contact of Expansion Interfaces (CN28/CN29) or Damaged Isolation Circuit
Contour Jitter During Machining (Expansion Axes) → FC240 Data Distribution Delay or Filter Circuit Failure
System Startup Reports "DDB Board Not Recognized" → Communication Fault between FC240 and FC230B or Board Card Damage
Get a Quote