jancd-fc110
May 23, 2026

jancd-fc110

JANCD-FC110 (Yaskawa YASNAC I80 I/O Interface Board) Brand: Yaskawa Electric Model: JANCD-FC110 (Rev. B01, DF9200740-XX) Type: CNC I/O Interface PCB (Slave I/O Board) Applicable System: YASNAC I80 / I80M CNC Status: EOL; available as used / refurbished / new surplus

Description

1. Overview

JANCD-FC110 is a slave I/O interface board for the Yaskawa YASNAC I80 CNC platform. It acts as an expansion I/O hub that connects the main CNC controller to external machine I/O devices (sensors, actuators, switches). It works alongside the main I/O board (e.g., JANCD-1021) to extend system I/O capacity for complex machine tools.

2. Specifications

  • Model: JANCD-FC110 (FC110)

  • Manufacturer: Yaskawa Electric

  • Revision: B01 (common), A01 (older)

  • Part Number: DF9200740-B01

  • System Compatibility: YASNAC I80, I80M

  • Board Type: Slave I/O Interface PCB

  • I/O Points: 64 Inputs / 32 Outputs (DC24V, opto-isolated)

  • Input Type: NPN/PNP compatible, 24VDC sink/source

  • Output Type: Transistor (0.3A/point max), opto-isolated

  • Power: 24VDC ±10%, ~200mA

  • Operating Temp: 0°C to +55°C

  • Dimensions: 267 mm × 152 mm (10.5" × 6")

  • Weight: ~0.4 kg

  • Form Factor: I80 standard slot (backplane: JANCD-FC006)

  • Shipping Weight: ~0.9 kg (2 lbs)


3. Key Functions

  • I/O Expansion: Adds 64IN / 32OUT to the I80 CNC system.

  • Signal Conditioning: Opto-isolation for noise immunity and CNC protection.

  • High-Speed I/O: 1ms refresh cycle for real-time machine control.

  • Slave Communication: High-speed link to main I/O board (JANCD-1021) via backplane.

  • LED Status Indication: On-board LEDs for power, communication, and I/O status.

  • Wiring Interface: Screw-terminal connectors for field wiring.


4. Compatibility

  • Backplane: JANCD-FC006 (I80 main base)

  • CNC Controllers: YASNAC I80, I80M

  • Main I/O Board: JANCD-1021 (required for operation)

  • Related Boards:

    • JANCD-FC100B/C: HIF Communication Board

    • JANCD-FC008: Axis Control Board

    • JANCD-FC050: Local I/O Board


5. Rev B01 Improvements

  • Enhanced Isolation: Higher surge immunity for harsh environments.

  • Lower Power Consumption: Reduced current draw (~200mA).

  • Improved Connector Reliability: Gold-plated contacts for long-term stability.

  • Updated Firmware: Better error handling and auto-recovery.


6. Notes

  • EOL Status: Discontinued by Yaskawa; only used/refurbished/new surplus available.

  • Configuration: Requires setup in I80 CNC parameters to enable I/O mapping.

  • Wiring: Input COM = 24V+, Output COM = 24V– (avoid reverse polarity).


Get a Quote