A06B-6250-H060
May 22, 2026

A06B-6250-H060

Model: A06B-6250-H060 Type: Bi spindle amplifier Brand: FANUC Application: Spindle driving for CNC machining equipment

Description

1. General Information

  • Model: A06B-6250-H060

  • Type: αiPS 60HV‑B (400V input power supply)

  • Manufacturer: FANUC

  • Series: Alpha i‑B (62xx series, 400V AC drives)

  • Application: Main power supply for CNC machine tools, servo & spindle amplifiers

2. Electrical Specifications

  • Input: 3‑phase AC 380–480V, 50/60Hz

  • Output DC: 537–679V

  • Rated power: 60kW (peak 72kW)

  • Control power: Single‑phase AC 200–240V, 50/60Hz

  • Regeneration: Built‑in regenerative circuit

  • Cooling: Forced air cooling with fan alarm detection

3. Mechanical & Environmental

  • Dimensions (H×W×D): 380 × 130 × 272 mm

  • Weight: Approx 7.0 kg

  • Protection: IP20 (cabinet mounting)

  • Operating temp: 0°C ~ +60°C (inlet air)

  • Storage temp: ‑40°C ~ +85°C

  • Humidity: 5%–95% RH, non‑condensing

4. Key Features

  • 400V direct input: No transformer needed for 380–480V grids

  • High‑efficiency power conversion with low heat generation

  • Regenerative energy return to line during motor deceleration

  • Compact & thin design for space‑saving cabinet layout

  • Comprehensive protection: overvoltage, undervoltage, overcurrent, overheat, fan fault

  • LED status indicators for power, alarm, and regeneration

5. Compatibility

  • CNC systems: FANUC 0i‑B/F, 30i/31i/32i‑B series

  • Servo amplifiers: αiSV‑B series (400V type)

  • Spindle amplifiers: αiSP‑B series (400V type)

6. Common Alarm Codes

  • AL‑01: Overcurrent

  • AL‑02: Overvoltage

  • AL‑03: Undervoltage

  • AL‑04: Overheat

  • AL‑05: Regeneration error

  • AL‑06: Cooling fan abnormality

7. Maintenance

  • Clean air filter monthly

  • Check cooling fan operation regularly

  • Inspect power terminals and cables quarterly

  • Verify regeneration function annually

8. Safety Notes

  • High residual voltage remains after power‑off; wait ≥10 minutes before touching terminals

  • Only qualified technicians may perform installation and maintenance

  • Ensure reliable equipment grounding