A06B-6240-H211
May 22, 2026

A06B-6240-H211

Model: A06B-6240-H211 Type: αiSV 160/160‑B (Dual‑axis servo amplifier) Manufacturer: FANUC Series: Alpha i (62xx series, 200V AC drives) Application: Dual‑axis high‑power servo drive for CNC machine tools, robotics, and automation systems

Description

1. General Information

  • Model: A06B-6240-H211

  • Type: αiSV 160/160‑B (Dual‑axis servo amplifier)

  • Manufacturer: FANUC

  • Series: Alpha i (62xx series, 200V AC drives)

  • Application: Dual‑axis high‑power servo drive for CNC machine tools, robotics, and automation systems

2. Electrical Specifications

  • Main input: 3‑phase DC 283–339V (from αiPS power supply)

  • Control power: Single‑phase AC 200–240V, 50/60Hz

  • Output: 2‑axis independent drive

    • Peak current per axis: 45A

    • Capacity: 160/160 (A·s)

    • Max output voltage: AC 240V

  • Regeneration: Built‑in regenerative circuit

  • Cooling: Forced air cooling with fan fault detection

3. Mechanical & Environmental

  • Dimensions (H×W×D): 380 × 90 × 272 mm

  • Weight: Approx 5.5 kg

  • Protection: IP20 (cabinet mounting)

  • Operating temp: 0°C ~ +60°C (inlet air)

  • Storage temp: ‑40°C ~ +85°C

  • Humidity: 5%–95% RH, non‑condensing

4. Key Features

  • Dual‑axis high‑performance drive for medium–large servo motors

  • High‑resolution encoder interface (incremental/absolute) for precision positioning

  • Three‑loop control (current/speed/position) with fast dynamic response

  • Comprehensive protection: overcurrent, overvoltage, undervoltage, overheat, short circuit, encoder fault

  • Absolute encoder backup (capacitor maintains position ~10 min after power‑off)

  • Leakage detection for motor/power cable insulation degradation

  • LED status indicators for power, alarm, and regeneration

5. Compatibility

  • CNC systems: FANUC 0i‑B/F, 30i/31i/32i‑B series

  • Servo motors: αiS, αiB series 200V AC servo motors

  • Power supply: αiPS‑B series (e.g., A06B‑6140‑H037)

6. Common Alarm Codes

  • AL‑01: Overcurrent

  • AL‑02: Overvoltage

  • AL‑03: Undervoltage

  • AL‑04: Overheat

  • AL‑05: Regeneration fault

  • AL‑06: Fan abnormality

  • AL‑07: Encoder error

7. Maintenance

  • Clean air filter monthly

  • Check cooling fan operation regularly

  • Inspect power terminals and cables quarterly

  • Verify regeneration function annually

8. Safety Notes

  • High residual voltage remains after power‑off; wait ≥10 minutes before touching terminals

  • Only qualified technicians may perform installation and maintenance

  • Ensure reliable equipment grounding


Get a Quote