A06B-6140-H037
May 22, 2026

A06B-6140-H037

Model: A06B-6140-H037 Type: αiPS-37 (Alpha i Power Supply) Manufacturer: FANUC Application: High‑power main DC power supply for αi servo/spindle amplifiers in CNC systems

Description

1. General Information

  • Model: A06B-6140-H037

  • Type: αiPS-37 (Alpha i Power Supply)

  • Manufacturer: FANUC

  • Application: High‑power main DC power supply for αi servo/spindle amplifiers in CNC systems

2. Electrical Specifications

  • Input: 3‑phase AC 200–240V, 153A @200V, 50/60Hz

  • Output: DC 283–339V

  • Rated power: 43kW

  • Peak power: 84kW

  • Control power: Built‑in 24VDC supply for servo logic

  • Regeneration: Built‑in regenerative circuit

3. Environmental & Mechanical Data

  • Operating temperature: 0°C ~ 55°C, non‑condensing

  • Storage temperature: -20°C ~ 70°C

  • Humidity: 5%–95% RH, non‑condensing

  • Protection grade: IP20

  • Installation: Vertical cabinet mounting

  • Dimensions (H×W×D): 380 × 150 × 272 mm

  • Weight: Approx 10 kg

4. Main Features

  • High‑efficiency power conversion for high‑load αi drives

  • Regenerative energy feedback to reduce power consumption

  • Comprehensive protection: overcurrent, overvoltage, undervoltage, overheat, short circuit

  • LED status indicators for power, alarm, and regeneration

  • Forced‑air cooling with fault detection

  • Compact, modular design for easy integration

5. Compatibility

  • CNC systems: FANUC 0i‑F, 16i/18i/21i‑B, 30i/31i/32i‑B series

  • Servo amplifiers: αiSV series

  • Spindle amplifiers: αiSP series

  • Motor series: αi‑B servo and spindle motors

6. Common Alarm Codes

  • PS0001: Input voltage abnormality

  • PS0002: DC bus overvoltage

  • PS0003: DC bus undervoltage

  • PS0004: Overcurrent

  • PS0005: Overheat

  • PS0006: Regeneration fault

  • PS0007: Cooling fan abnormality

7. Maintenance

  • Clean air filter and dust monthly

  • Check cooling fan operation regularly

  • Inspect power terminals and cables quarterly

  • Test insulation and regeneration function annually

8. Safety Precautions

  • Only qualified technicians may perform installation and maintenance

  • High residual voltage remains after power‑off; wait ≥10 minutes before touching terminals

  • Keep ventilation paths unobstructed

  • Use genuine FANUC replacement parts

  • Ensure reliable equipment grounding


Get a Quote