A06B-6200-H008
May 22, 2026

A06B-6200-H008

Model: A06B-6200-H008 Type: αiPS-15i (PSM-15i), power supply module for αi servo/spindle amplifiers Manufacturer: FANUC Series: Alpha i (A06B-6200 series)

Description

1. General Information

  • Model: A06B-6200-H008

  • Type: αiPS-15i (PSM-15i), power supply module for αi servo/spindle amplifiers

  • Manufacturer: FANUC

  • Series: Alpha i (A06B-6200 series)

  • Application: CNC machines, machining centers, lathes; supplies DC bus to αi servo (SVM) and

2. Electrical Specifications

  • Input: 3‑phase AC 200–240V, 50/60Hz

  • Rated Input Current: 33A @ 200V

  • Rated Power: 9.4 kW

  • DC Output Voltage: 283–339 VDC (rectified bus)

  • Regeneration: Built‑in regenerative circuit (energy recovery)

  • Cooling: Forced air (internal fan + heatsink)

3. Environmental & Mechanical

  • Operating Temp: 0°C to +55°C

  • Storage Temp: -20°C to +70°C

  • Humidity: 5%–95% RH, non‑condensing

  • Protection: IP20

  • Mounting: Vertical cabinet mount

  • Dimensions (H×W×D): 380 × 60 × 272 mm

  • Weight: Approx. 4 kg

  • Standards: EN50178, UL508C

4. Key Features

  • 9.4 kW high‑efficiency power supply for medium‑to‑high power CNC systems

  • 60 mm slim width (saves cabinet space)

  • Integrated regeneration: no external resistor needed for most applications

  • Leakage detection: monitors motor/power line insulation degradation

  • LED status: power, alarm, ready

  • Full protection: overvoltage, undervoltage, overcurrent, overheat, fan failure

5. Compatibility

  • CNC Systems: FANUC 0i‑B/D, 30i‑B, 16i/18i/21i

  • Servo Amplifiers: αiSVM series (A06B-6114/6117‑Hxxx)

  • Spindle Amplifiers: αiSPM series (A06B-6141‑Hxxx)

  • Motor Series: αi‑M / αi‑S (servo), αi‑B (spindle)

6. Common Alarms

  • AL400: Overvoltage

  • AL401: Undervoltage

  • AL402: Overcurrent

  • AL403: Overheat

  • AL404: Fan failure

  • AL405: Regeneration error

7. Maintenance & Safety

  • Maintenance: Clean air filters monthly; inspect fan quarterly; check terminals/cables quarterly.

  • Safety: High DC bus voltage remains after power‑off; only qualified technicians to service; ensure proper grounding.