A06B-6114-H206
May 22, 2026

A06B-6114-H206

1. General Information Model: A06B-6114-H206 Type: 2‑axis servo amplifier, SVM2-20/40i (αiSV2-20/40 HRV3) Manufacturer: FANUC Series: Alpha i servo module (A06B-6114 series)

Description

1. General Information

  • Model: A06B-6114-H206

  • Type: 2‑axis servo amplifier, SVM2-20/40i (αiSV2-20/40 HRV3)

  • Manufacturer: FANUC

  • Series: Alpha i servo module (A06B-6114 series)

  • 2. Electrical Specifications

    • DC Input Voltage: 283–339 VDC

    • Rated Input Power: 7 kW

    • Rated Output Voltage: 240 VAC (max)

    • Rated Output Current (continuous):

      • L‑axis: 6.5 A

      • M‑axis: 13 A

    • Control Method: HRV3 (High‑Response Vector)

    • Feedback: Incremental / serial encoder (αi encoder compatible)

    • Cooling: Forced air (internal fan + heatsink)

  • 3. Environmental & Mechanical

    • Operating Temperature: 0°C to +55°C

    • Storage Temperature: -20°C to +70°C

    • Humidity: 5%–95% RH, non‑condensing

    • Protection Grade: IP20

    • Mounting: Vertical cabinet mount

    • Dimensions (H×W×D): 380 × 60 × 205 mm

    • Weight: Approx. 4.2 kg

    • Standards: EN50178, UL508C

  • 4. Key Features

    • 2‑axis integrated drive: saves space and wiring

    • HRV3 control: ultra‑high response, low vibration

    • 7 kW rated power for medium‑to‑heavy duty feed axes

    • Dual independent current ratings: 6.5 A + 13 A (L/M axes)

    • Built‑in regenerative circuit: energy recovery

    • LED status indicators: power, alarm, operation

    • Full protection: overcurrent, overvoltage, undervoltage, overheat, fan failure, encoder error

    • Compact & slim design: 60 mm width, ~30% less cabinet space than older models

  • 5. Compatibility

    • CNC Systems: FANUC 0i‑B/D, 30i‑B, 16i/18i/21i series

    • Servo Motors: αi‑M / αi‑S series (20/40 class motors)

    • Power Supply: αiPS series (e.g., A06B-6110‑Hxxx)

  • 6. Common Alarms

    • SV0401: Servo amplifier overheat

    • SV0403: Overcurrent (L‑axis)

    • SV0404: Overcurrent (M‑axis)

    • SV0405: Overvoltage

    • SV0406: Undervoltage

    • SV0417: Fan failure

  • 7. Maintenance & Safety

    • Maintenance: Clean air filters monthly; inspect cooling fan quarterly; check terminals/cables quarterly.

    • Safety: Only qualified technicians to service; high residual voltage remains after power‑off; ensure proper grounding.


Get a Quote