A06B-6111-H011
May 22, 2026

A06B-6111-H011

Model: A06B-6111-H011 (#H550 / #H570) Type: αiSP-11 (SPM-11i) spindle amplifier Manufacturer: FANUC Series: Alpha i spindle module Application: High‑power spindle drive for CNC machines, machining centers, lathes

Description

1. General Information

  • Model: A06B-6111-H011 (#H550 / #H570)

  • Type: αiSP-11 (SPM-11i) spindle amplifier

  • Manufacturer: FANUC

  • Series: Alpha i spindle module

  • Application: High‑power spindle drive for CNC machines, machining centers, lathes

2. Electrical Specifications

  • DC Input Voltage: 283–339 VDC

  • Rated Input Power: 13.2 kW

  • Rated Output Voltage: 240 VAC

  • Rated Output Current: 48 A (continuous)

  • Control Interface: Type A (FANUC spindle I/F)

  • Feedback: Incremental / serial encoder compatible

  • Cooling: Forced air (internal fan + heatsink)

3. Environmental & Mechanical

  • Operating Temperature: 0°C to +55°C

  • Storage Temperature: -20°C to +70°C

  • Humidity: 5%–95% RH, non‑condensing

  • Protection Grade: IP20

  • Mounting: Vertical cabinet mount

  • Weight: Approx. 5.0 kg

  • Standards: EN50178, UL508C

4. Key Features

  • 13.2 kW high‑power spindle drive for heavy machining

  • High‑speed & high‑torque spindle control

  • Built‑in regenerative circuit for energy recovery

  • LED status indicators for power, alarm, operation

  • Full protection: overcurrent, overvoltage, undervoltage, overheat, fan failure

  • Compact αi series footprint

5. Compatibility

  • CNC Systems: FANUC 0i‑B/D, 30i‑B, 16i/18i/21i series

  • Spindle Motors: αi series spindle motors (e.g., αiSP‑11)

  • Power Supply: αiPS series power supply modules

6. Common Alarms

  • SP9001: Spindle motor overheat

  • SP9002: Excessive speed error

  • SP9003: Spindle overcurrent

  • SP9004: Spindle overvoltage

  • SP9005: FSSB/spindle communication error

7. Maintenance & Safety

  • Maintenance: Clean air filters monthly; inspect cooling fan quarterly; check terminals/cables quarterly.

  • Safety: Only qualified technicians to service; high residual voltage remains after power‑off; ensure proper grounding.