A06B-6117-H106
Description
1. General Information
Model: A06B-6117-H106
Type: αiSV-160 single-axis servo amplifier
Brand: FANUC
Application: High-precision single-axis drive for CNC machines, robotics, and automation equipment
2. Electrical Specifications
DC Input Voltage: 283–339 VDC
Rated Power: 11 kW
Rated Continuous Output Current: 45 A
Peak Output Current: 90 A
Max Output AC Voltage: 240 V
Control Algorithm: HRV3 digital vector control
Feedback: Serial absolute/incremental encoder
Communication: FSSB optical fiber bus
Cooling: Forced air cooling (internal fan + external heatsink fans)
Insulation Class: H (180°C)
3. Environmental & Mechanical
Operating Temperature: 0°C ~ +55°C
Storage Temperature: -20°C ~ +70°C
Humidity: 5%–95% RH, non-condensing
Protection Grade: IP20
Installation: Vertical cabinet mount
Ventilation Clearance: Min. 50 mm top/bottom
Dimensions (H×W×D): 380 × 90 × 272 mm
Weight: Approx. 4.0 kg
4. Key Features
Compact, slim design (90 mm width) saves cabinet space
High response and positioning accuracy (μm-level)
Full protection: overcurrent, overvoltage, undervoltage, overheating, fan failure
LED status indicators for power, alarm, and operation
Built-in backup capacitor for absolute encoder (≈10 min retention)
Compatible with regenerative power supply units
5. Compatibility
CNC Systems: FANUC 0i-B/D, 30i-B series
Servo Motors: αiS series (e.g., αiS-22/30/40)
Power Supply: αiPS series power supply modules
6. Installation Notes
Disconnect all power; wait 15 minutes for capacitor discharge.
Mount vertically on a rigid cabinet rail.
Connect DC bus to αiPS power supply.
Connect motor power and encoder cables.
Insert FSSB optical fiber.
Ensure reliable chassis ground.
Verify wiring before power-on.
7. Common Alarms
ALM300: Overcurrent
ALM430: Internal overheating
ALM510: FSSB communication error
AL-UV: DC bus undervoltage
AL-FAN: Cooling fan fault
8. Maintenance
Clean air filter and heatsink monthly.
Check fan operation quarterly.
Tighten terminals and inspect cables quarterly.
Test insulation resistance annually.
9. Safety
Only qualified technicians may install/service.
High residual voltage remains after power-off.
Do not block ventilation openings.
Use genuine FANUC cables and parts.
Maintain stable, low-resistance ground.
Get a Quote