A06B-6111-H030
Model: A06B-6141-H030
Type: αiSP-30 spindle amplifier
Manufacturer: FANUC
Application: Spindle drive for CNC lathes, machining centers and milling machines
Description
1. General Information
Model: A06B-6141-H030Type: αiSP-30 spindle amplifierManufacturer: FANUCApplication: Spindle drive for CNC lathes, machining centers and milling machines
2. Electrical Specifications
DC input voltage: 283-339VDCRated power: 35kWRated output current: 133AMax output AC voltage: 240VControl mode: Full digital vector controlFeedback: Serial incremental and absolute encoderCommunication: FSSB optical fiber busCooling type: Forced air coolingInsulation class: Class H, 180°C
3. Environmental & Mechanical Parameters
Operating temperature: 0°C ~ 55°CStorage temperature: -20°C ~ 70°CHumidity: 5%-95%RH, non-condensingProtection grade: IP20Installation way: Vertical mounting inside control cabinetMinimum ventilation gap: 50mm top and bottomWeight: Approx 8.5kg
4. Main Features
High power output for heavy cutting workSupports spindle positioning and rigid tappingBuilt-in multiple safety protection functionsHigh stability and fast dynamic responseLED indicators for operating and alarm statusCompatible with regenerative power supply modules
5. Compatibility
Applicable CNC system: FANUC 0i-B/D, 30i-B seriesMatching spindle motor: αiSP series motorMatched power unit: αiPS power supply series
6. Installation Instructions
Disconnect all power, wait 15 minutes for voltage discharge
Fix the module vertically on cabinet mounting rail
Connect DC bus cable to power supply module
Wire spindle motor power cable and encoder cable
Connect FSSB optical communication line
Complete reliable chassis grounding
Check wiring condition and perform power-on test
7. Common Alarm Codes
SP9001: Motor overheating faultSP9002: Speed deviation abnormalityAL-OC: Output overcurrentAL-OV: DC bus overvoltageAL-UV: DC bus undervoltageAL-FAN: Cooling fan failure
8. Daily Maintenance
Clean dust and air filter every monthCheck fan running state regularlyInspect cable aging and terminal tightness quarterlyTest internal insulation performance annually
9. Safety Precautions
Only qualified technicians can carry out installation and maintenanceResidual high voltage exists after power offKeep ventilation passages unblockedAdopt original FANUC cables and accessoriesEnsure effective and stable equipment grounding
Get a Quote