A06B-6140-H026
Description
1. General Information
Model: A06B-6140-H026
Type: αiPS-26 (Alpha i Power Supply Module)
Manufacturer: FANUC
Function: 3‑phase regenerative power supply for αi servo/spindle amplifiers; provides common DC bus and built‑in 24 V control power.
Application: CNC machine tools, machining centers, high‑speed automation requiring up to ~30 kW.
2. Electrical Specifications
Input: 3‑phase AC 200–240 V ±10%, 50/60 Hz
Rated Input Current: 106 A @ 200 V
Rated Power: 29.8 kW
DC Bus Output: 283–339 VDC
Rated DC Output Current: ~110 A
Regeneration: Integrated (regenerative feedback to line)
Control Power: Built‑in 24 VDC
Cooling: Forced air (internal + external fan)
Insulation Class: H (180°C)
3. Environmental & Mechanical
Operating Temp: 0°C to +40°C
Storage Temp: −20°C to +70°C
Humidity: 5–95% RH, non‑condensing
Altitude: ≤1000 m (derate above)
Protection: IP20
Mounting: Vertical in cabinet
Clearance: ≥50 mm top/bottom
Dimensions (W×H×D): approx 130 × 300 × 85 mm
Weight: approx 6.5–7 kg
4. Key Features
High power: 29.8 kW for medium‑to‑large systems.
Common DC bus: Works with αi servo/spindle drives.
Regenerative: Reduces energy waste and heat.
Built‑in protection: Overcurrent, overvoltage, undervoltage, overtemperature, fan fault, phase loss.
LEDs: Power, Alarm, DC Ready.
FSSB: Digital link to CNC (30i‑B / 0i‑B etc.).
5. Compatibility
CNC: FANUC 30i‑B, 31i‑B, 32i‑B, 0i‑B
Drives: αiSV servo, αiSP spindle amplifiers
Series: Matches αiPS‑15 / αiPS‑55 family
6. Installation & Wiring
Safety: Disconnect all power; wait ≥15 min for capacitors to discharge.
Mounting: Vertical; maintain cooling clearances.
AC Input: Connect 3‑phase + PE.
DC Bus: Link DC+/DC− to servo/spindle units.
Grounding: Reliable PE to cabinet ground.
Check: Verify fan operation after power‑on.
7. Common Alarms
AL1: Main circuit overcurrent
AL2: Cooling fan stop/fault
AL3: Heat sink overtemperature
AL4: DC bus undervoltage
AL5: Precharge failure
AL6: Input power abnormal (phase loss, unbalance)
AL7: DC bus overvoltage
8. Maintenance
Monthly: Clean vents, check fans.
Quarterly: Retorque terminals, inspect cables.
Annually: Check capacitors, fans, insulation.
9. Safety Notes
High voltage remains after power‑off; wait before servicing.
Install only in grounded, locked cabinets.
Use genuine FANUC cables and parts.
Keep ventilation clear to avoid overheating.
Get a Quote