A06B-6220-H030
May 22, 2026

A06B-6220-H030

Model: A06B-6220-H030 (#H600) Series: αiSP‑B (Alpha i Spindle Amplifier) Type: SPM‑30iB Manufacturer: FANUC Function: 3‑phase spindle drive for αi spindle motors, powered from common DC bus. Application: CNC machining centers, milling machines, high‑speed spindles.

Description

1. General Information

  • Model: A06B-6220-H030 (#H600)

  • Series: αiSP‑B (Alpha i Spindle Amplifier)

  • Type: SPM‑30iB

  • Manufacturer: FANUC

  • Function: 3‑phase spindle drive for αi spindle motors, powered from common DC bus.

  • Application: CNC machining centers, milling machines, high‑speed spindles.

2. Electrical Specifications

  • DC Input: 283–339 VDC

  • Input Current: 124 A @ 283 VDC

  • Output: 3‑phase AC 200 V class

  • Rated Output Current: 148 A

  • Max Motor Power: ~30 kW (spindle)

  • Control Power: From DC bus (internal 24 VDC)

  • Cooling: Forced air, internal + external fan

  • Insulation Class: Class H (180°C)

3. Mechanical & Environment

  • Operating Temp: 0°C to +55°C

  • Storage Temp: −20°C to +70°C

  • Humidity: 5–95%RH (non‑condensing)

  • Altitude: ≤1000 m (derate 1% per 100 m above)

  • Protection: IP20 (front)

  • Mounting: Vertical panel/flange mount

  • Dimensions (W×H×D): Approx 130 × 300 × 85 mm

  • Weight: Approx 5–6 kg

4. Key Features

  • High‑power spindle drive: Up to 30 kW for heavy cutting.

  • Common DC bus: Works with αiPS power supplies.

  • Fast response: High‑speed spindle positioning & rigid tapping.

  • Built‑in protection: Overcurrent, overvoltage, undervoltage, overtemperature, fan fault, short circuit.

  • LED indicators: Power, alarm, spindle ready.

  • FSSB communication: Digital link to CNC (30i/0i‑B).

5. Compatibility

  • CNC Systems: FANUC 30i‑B, 31i‑B, 32i‑B, 0i‑B

  • Motors: αi series spindle motors (e.g., αiSP‑30)

  • Power Supply: αiPS‑15/26/55 (A06B‑6140‑Hxxx)

6. Installation & Wiring

  1. Safety: Cut power, wait ≥15 min for DC bus discharge.

  2. Mounting: Vertical installation; maintain ≥50 mm top/bottom clearance.

  3. DC Bus: Connect DC+/DC− from αiPS module.

  4. Motor: 3‑phase U/V/W + encoder cable to spindle motor.

  5. Grounding: Secure PE to cabinet ground.

  6. Fans: Verify internal/external fan operation after power‑on.

7. Common Alarms

  • AL01: Overcurrent

  • AL02: Fan failure

  • AL03: Overtemperature

  • AL04: DC bus undervoltage

  • AL05: Precharge failure

  • AL06: Input power abnormal

  • AL07: DC bus overvoltage

8. Maintenance

  • Monthly: Clean vents, check fans.

  • Quarterly: Retorque terminals, inspect cables.

  • Annually: Check capacitors, fans, and insulation.

9. Safety Notes

  • High voltage remains after power‑off; wait before servicing.

  • Install only in grounded, locked cabinets.

  • Use genuine FANUC cables and parts.

  • Ensure proper cooling to avoid overheating.


Get a Quote