A06B-6220-H030
Description
1. General Information
Model: A06B-6220-H030 (#H600)
Series: αiSP‑B (Alpha i Spindle Amplifier)
Type: SPM‑30iB
Manufacturer: FANUC
Function: 3‑phase spindle drive for αi spindle motors, powered from common DC bus.
Application: CNC machining centers, milling machines, high‑speed spindles.
2. Electrical Specifications
DC Input: 283–339 VDC
Input Current: 124 A @ 283 VDC
Output: 3‑phase AC 200 V class
Rated Output Current: 148 A
Max Motor Power: ~30 kW (spindle)
Control Power: From DC bus (internal 24 VDC)
Cooling: Forced air, internal + external fan
Insulation Class: Class H (180°C)
3. Mechanical & Environment
Operating Temp: 0°C to +55°C
Storage Temp: −20°C to +70°C
Humidity: 5–95%RH (non‑condensing)
Altitude: ≤1000 m (derate 1% per 100 m above)
Protection: IP20 (front)
Mounting: Vertical panel/flange mount
Dimensions (W×H×D): Approx 130 × 300 × 85 mm
Weight: Approx 5–6 kg
4. Key Features
High‑power spindle drive: Up to 30 kW for heavy cutting.
Common DC bus: Works with αiPS power supplies.
Fast response: High‑speed spindle positioning & rigid tapping.
Built‑in protection: Overcurrent, overvoltage, undervoltage, overtemperature, fan fault, short circuit.
LED indicators: Power, alarm, spindle ready.
FSSB communication: Digital link to CNC (30i/0i‑B).
5. Compatibility
CNC Systems: FANUC 30i‑B, 31i‑B, 32i‑B, 0i‑B
Motors: αi series spindle motors (e.g., αiSP‑30)
Power Supply: αiPS‑15/26/55 (A06B‑6140‑Hxxx)
6. Installation & Wiring
Safety: Cut power, wait ≥15 min for DC bus discharge.
Mounting: Vertical installation; maintain ≥50 mm top/bottom clearance.
DC Bus: Connect DC+/DC− from αiPS module.
Motor: 3‑phase U/V/W + encoder cable to spindle motor.
Grounding: Secure PE to cabinet ground.
Fans: Verify internal/external fan operation after power‑on.
7. Common Alarms
AL01: Overcurrent
AL02: Fan failure
AL03: Overtemperature
AL04: DC bus undervoltage
AL05: Precharge failure
AL06: Input power abnormal
AL07: DC bus overvoltage
8. Maintenance
Monthly: Clean vents, check fans.
Quarterly: Retorque terminals, inspect cables.
Annually: Check capacitors, fans, and insulation.
9. Safety Notes
High voltage remains after power‑off; wait before servicing.
Install only in grounded, locked cabinets.
Use genuine FANUC cables and parts.
Ensure proper cooling to avoid overheating.
Get a Quote