Model: A06B-6110-H055 (αiPS-55, PSM-55i) Type: 3‑phase regenerative power supply module (Alpha i series) Manufacturer: FANUC Description: High‑power common DC‑bus supply for αiSV servo amplifiers and αiSP spindle amplifiers; designed for heavy‑duty CNC machines, large machining centers, and high‑torque spindle applications. Function: Provides main motor power + control power to servo units; includes regeneration (feeds deceleration energy back to the line).

Description

1. General Information

  • Model: A06B-6110-H055 (αiPS-55, PSM-55i)

  • Type: 3‑phase regenerative power supply module (Alpha i series)

  • Manufacturer: FANUC

  • Description: High‑power common DC‑bus supply for αiSV servo amplifiers and αiSP spindle amplifiers; designed for heavy‑duty CNC machines, large machining centers, and high‑torque spindle applications.

  • Function: Provides main motor power + control power to servo units; includes regeneration (feeds deceleration energy back to the line).

  • Manual Reference: B‑65282EN

2. Electrical Specifications

  • Input: 3‑phase AC 200–240 V ±10%, 50/60 Hz

  • Rated Input Current: 228 A @ 200 V

  • Rated Input Power: 65 kW

  • DC Link Output: 283–339 VDC

  • Rated Output Current: 234 A DC

  • Regeneration: Built‑in (no external resistor needed)

  • Control Power: 24 VDC (internal, for servo logic)

  • Cooling: Forced air (internal + external fan)

  • Insulation Class: Class H (180 °C)

3. Environmental & Mechanical

  • Operating Temp: 0 °C to +55 °C

  • Storage Temp: −20 °C to +70 °C

  • Humidity: 5–95% RH, non‑condensing

  • Altitude: ≤1000 m (derate 1%/100 m above)

  • Protection: IP20 (front)

  • Mounting: Vertical in cabinet; ≥100 mm clearance top/bottom

  • Dimensions (W×H×D): 300 mm × 350 mm × 250 mm

  • Weight: Approx. 20 kg (44 lbs)

4. Key Features

  • 65 kW high‑power: For large servo/spindle combinations

  • Regenerative: Reduces energy waste and heat

  • Common DC bus: Synchronizes multiple axes, reduces wiring

  • Dual‑fan cooling: Heavy‑duty thermal management

  • Built‑in protection: Overcurrent, overvoltage, undervoltage, overtemperature, fan fault, input phase loss

  • LED indicators: Power, alarm, DC link ready

  • Diagnostics: Real‑time monitoring via FSSB

5. Installation & Wiring

  1. Power off: Disconnect all AC power; wait ≥15 minutes for DC bus discharge.

  2. Mounting: Secure vertically to rigid rail; maintain airflow clearances.

  3. AC input: Connect L1/L2/L3 and PE (protective earth); use 120 mm² cables for 228 A.

  4. DC bus: Connect DC+ / DC− to servo/spindle amplifiers; torque terminals to 2.5–3.0 N·m.

  5. Control power: 24 VDC to CNC/servo logic.

  6. Fans: Verify internal/external fans run on power‑on.

6. Alarm Codes (Common)

  • AL‑1: Main circuit overcurrent (short, ground fault, overload)

  • AL‑2: Cooling fan stopped (replace fan immediately)

  • AL‑3: Heatsink overtemperature (poor ventilation, fan blocked)

  • AL‑4: DC link undervoltage (input loss, phase failure)

  • AL‑5: Precharge failure (capacitor bank fault)

  • AL‑6: Input power abnormal (phase imbalance, voltage drop)

  • AL‑7: DC link overvoltage (regeneration overload, faulty servo)

7. Maintenance

  • Monthly: Clean air filters; check fan operation (replace if noisy/stuck).

  • Quarterly: Torque check on all power terminals; inspect cables for wear.

  • Annual: Test regeneration function; check DC bus capacitor ripple.

8. Safety Precautions

  • Only qualified electricians may install/service.

  • High voltage remains 15+ minutes after power‑off—risk of shock.

  • Do not block ventilation—fire/overheating hazard.

  • Use only FANUC‑specified cables/connectors.

  • Properly ground the module chassis.