A06B-6114-H304
Description
1. General Information
Model: A06B-6114-H304 (SVM3‑20/20/40i, αiSV‑20/20/40)
Type: Three‑axis integrated AC servo amplifier (Alpha i series)
Manufacturer: FANUC
Description: Compact, high‑performance 3‑axis drive for CNC machine tools, machining centers, lathes, and multi‑axis automation equipment.
Applicable Motors: FANUC αi series servo motors
Manual Reference: B‑63282EN (FANUC αi Servo Amplifier Series)
2. Electrical Specifications
Input Voltage: 3‑phase AC 200–240 V ±10%, 50/60 Hz
DC Link Voltage: 283–339 V
Rated Input Power: 9.5 kW
Output Voltage: 0–240 V AC, 3‑phase
Continuous Output Current (RMS):
Axis L/M: 6.5 A each
Axis N: 13 A
Peak Output Current: 2× continuous (max 0.5 s)
Control Method: Full digital vector control (HRV3)
Feedback Interface: Incremental encoder / serial absolute encoder
Communication: FSSB (FANUC Serial Servo Bus), 12 Mbps
Cooling: Forced air cooling (internal fan)
Insulation Class: Class H (180 °C)
3. Environmental & Mechanical
Operating Temperature: 0 °C to +55 °C
Storage Temperature: −20 °C to +70 °C
Humidity: 5–95% RH, non‑condensing
Protection Class: IP20 (front face)
Mounting: Vertical installation in control cabinet
Dimensions (W×H×D): 90 mm × 243 mm × 228 mm
Weight: Approx. 3.7 kg (8.25 lbs)
4. Key Features
3‑axis integration: Saves cabinet space and reduces wiring
High‑speed response: HRV3 control, 1 μs cycle time
High positioning accuracy: Supports 1 μm level precision
Dual encoder support: Incremental / absolute serial encoder
Built‑in protection: Overcurrent, overvoltage, undervoltage, overtemperature, overload, encoder failure, fan fault
LED status indicators: Power, alarm, FSSB communication
Easy maintenance: Accessible fan replacement, modular design
5. Installation Instructions
Power off: Disconnect all power before installation or wiring.
Mounting: Install vertically on a rigid cabinet rail; maintain ≥50 mm clearance top and bottom for airflow.
Input wiring: Connect 3‑phase AC power (L1/L2/L3) and protective earth (PE).
Motor wiring: Connect motor power cables to U/V/W terminals for each axis.
Feedback wiring: Connect encoder cables to respective feedback connectors.
Communication wiring: Connect FSSB cable to CNC controller.
Terminal torque: Tighten all terminals to 1.2–1.5 N·m.
Fan check: Verify internal fan operates normally after power‑on.
6. Maintenance & Troubleshooting
Routine Maintenance
Clean air filter every 1–3 months.
Check fan operation monthly; replace if noisy or stopped.
Inspect terminals and cables for tightness or damage every 6 months.
Common Alarms
ALM 300 (Overcurrent): Motor short circuit, wiring fault, or axis overload.
ALM 430 (Overtemperature): Poor ventilation, blocked fan, or ambient temp too high.
ALM 510 (FSSB Error): Check FSSB cable, connector, or CNC communication setup.
ALM 01 (Fan Stop): Internal cooling fan failure; replace fan.
7. Safety Precautions
Installation and servicing must be performed by qualified electricians.
High voltage remains for ≥10 minutes after power‑off; wait before touching terminals.
Do not block ventilation openings—risk of overheating and fire.
Use only FANUC‑specified cables and connectors to ensure safety and compatibility.
Ground the amplifier housing properly to avoid electric shock.
Get a Quote