A06B-6130-K202
May 22, 2026

A06B-6130-K202

A06B-6130-K202 is a dedicated connector plug for regenerative discharge resistors, used with FANUC βi‑series 200V servo amplifiers (A06B-6130‑Hxxx). It provides a secure connection between the amplifier and external discharge resistors for regenerative energy absorption.

Description

General Description

A06B-6130-K202 is a dedicated connector plug for regenerative discharge resistors, used with FANUC βi‑series 200V servo amplifiers (A06B-6130‑Hxxx). It provides a secure connection between the amplifier and external discharge resistors for regenerative energy absorption.

Part Information

Part Number: A06B-6130-K202
Type: Discharge resistor connector (2‑pin)
Applicable Series: βiSV / βiSVM (200V class, A06B-6130‑Hxxx)
Manufacturer: FANUC
Function: Connect external regenerative discharge resistor

Electrical Specifications

Maximum rated voltage: 300V DC
Continuous rated current: 10A
Applicable wire size: 1.0mm² to 2.0mm² (16–20 AWG)
Contact resistance: ≤8mΩ
Insulation resistance: ≥100MΩ at 500V DC
Withstand voltage: 1500V AC for 1 minute

Mechanical & Material

Housing material: Flame‑retardant thermoplastic (UL94 V‑0)
Contact material: Tin‑plated copper alloy
Locking method: Screw lock (M2.5)
Approximate dimensions: 18mm × 25mm × 10mm
Approximate weight: 12g

Compatible Amplifiers

βiSV‑4A, βiSV‑20A, βiSV‑40A, βiSV‑80A
βiSVM‑40i, βiSVM‑80i, βiSVM‑160i (A06B-6130‑Hxxx series)

Features

Compact 2‑pin design for resistor connection
Vibration‑resistant screw‑locking structure
High‑temperature and flame‑retardant housing
Low contact resistance for safe energy discharge
Easy field wiring and replacement

Installation Instructions

Disconnect all power before wiring
Strip wire insulation to 6–7mm
Insert wires into the two resistor terminals
Tighten M2.5 screws to 0.5–0.6N·m
Align plug with amplifier resistor port and seat firmly
Verify tightness and insulation before power‑on

Safety Precautions

Observe voltage and current ratings strictly
Use only FANUC‑specified discharge resistors
Ensure wiring is insulated and secure to prevent short circuits
Do not use damaged or deformed connectors

Related Parts

A06B-6130-K200/K201: UVWPE power connectors
A06B-6130-H402/H403/H404: Regenerative resistors
A06B-6130-H002/H003: βi servo amplifiers


Get a Quote