A06B-6124-H106
Description
General Information
Model Identification
Part Number: A06B-6124-H106
Model: SVM1‑180HVi (αi SV180HV)
Series: Alpha i (αi)
Type: Single‑axis high‑voltage servo amplifier (400V AC)
Manufacturer: FANUC
Application: Heavy‑duty CNC machines, large machining centers, gantry systems, and high‑power automation axes.
Electrical Specifications
DC Bus Input (from αi PSM)
Voltage: 565–679V DC
Rated Input Power: 32kW
Control Power: External 24V DC ±10% (logic, FSSB, fan).
AC Output (to Servo Motor)
Rated Output Voltage: 480V AC (3‑phase)
Rated Output Current: 58A (RMS)
Peak Current: 180A (peak)
Output Frequency: Up to 400Hz
Control Method: Full‑digital vector control (position, speed, torque modes).
Regenerative Capability
Supports regenerative braking; energy fed back to DC bus via αi PSM.
Mechanical & Environmental Parameters
Construction: Yellow metal housing, vertical panel mount, heavy‑duty external heatsink.
Dimensions (W×H×D): 130mm × 380mm × 272mm
Weight: 9.0kg (19.84lbs)
Cooling: Dual built‑in replaceable axial fans + high‑capacity heatsink.
Operating Temperature: 0°C to +55°C (non‑condensing)
Storage Temperature: ‑20°C to +70°C
Humidity: 5%–95% RH (non‑condensing)
Protection Class: IP20 (cabinet installation).
Compatibility
Servo Motors: FANUC αi HV series (e.g., αi45/3000HVi, αi60/2500HV).
Power Supply: αi PSM 400V‑class (e.g., A06B‑6120‑H200).
CNC Systems: FANUC 30i/31i/32i‑B, 0i‑MF/TF (400V high‑power option).
Communication: FSSB fiber optic bus (100Mbps).
Feedback: Absolute/incremental encoders (αi pulse coder); built‑in backup capacitor (≈10‑minute hold, no homing after replacement).
Protection & Alarm Functions
Overcurrent (AL‑01): Main circuit overload or short circuit.
DC Bus Undervoltage (AL‑04) / Overvoltage (AL‑07)
Heatsink Overheat (AL‑03)
Fan Abnormal (AL‑02)
Encoder/Feedback Error
Regenerative Overload
Front‑panel 7‑segment LED displays real‑time status and alarm codes.
Installation Guidelines
De‑energize the entire system and perform lockout/tagout before installation.
Mount vertically on a robust cabinet plate; ensure ≥100mm clearance top and bottom for airflow.
Connect DC bus terminals to αi PSM; use high‑current cables and ensure reliable protective grounding.
Wire 24V control power and FSSB fiber cables per FANUC standard pinouts.
Verify all connections for tightness and correctness before restoring power; clear existing alarms before operation.
Safety Notice
High voltage present inside; wait ≥15 minutes after power‑off before opening the cover.
Installation, wiring, and maintenance must be performed by qualified professional electricians.
Use only genuine FANUC high‑current cables and connectors to avoid overheating and hazards.
Maintain unobstructed airflow; clean fans and heatsink dust regularly, replace faulty cooling components promptly.
Key Features
32kW / 58A rated output for heavy‑duty servo applications.
Robust 130mm width design for high‑power stability.
Built‑in absolute encoder backup capacitor eliminates homing after replacement.
FSSB fiber communication ensures high‑speed, noise‑immune data transfer.
Low‑loss IGBT power devices reduce heat generation and improve efficiency.
Get a Quote