A06B-6124-H104
Description
Model Identification
Part Number: A06B-6124-H104
Model: SVM1‑40HVi (αi SV40HV)
Series: Alpha i (αi)
Type: Single‑axis high‑voltage servo amplifier (400V AC)
Manufacturer: FANUC
Application: CNC machine tools, automation equipment, medium‑load servo axes.
Electrical Specifications
DC Bus Input (from αi PSM)
Voltage: 565–679V DC
Rated Input Power: 2.8kW
Control Power: External 24V DC ±10% (logic, FSSB, fan).
AC Output (to Servo Motor)
Rated Output Voltage: 480V AC (3‑phase)
Rated Output Current: 9.1A (RMS)
Peak Current: 40A (peak)
Output Frequency: Up to 400Hz
Control Method: Full‑digital vector control (position, speed, torque modes).
Regenerative Capability
Supports regenerative braking; energy fed back to DC bus via αi PSM.
Mechanical & Environmental Parameters
Construction: Yellow metal housing, vertical panel mount, external high‑efficiency heatsink.
Dimensions (W×H×D): 60mm × 380mm × 272mm
Weight: 3.8kg (8.38lbs)
Cooling: Built‑in replaceable axial fan + heatsink.
Operating Temperature: 0°C to +55°C
Storage Temperature: ‑20°C to +70°C
Humidity: 5%–95% RH (non‑condensing)
Protection Class: IP20 (cabinet installation).
Compatibility
Servo Motors: FANUC αi HV series (e.g., αi12/3000HVi, αi8/4000HV).
Power Supply: αi PSM 400V‑class (e.g., A06B‑6120‑H075).
CNC Systems: FANUC 30i/31i/32i‑B, 0i‑MF/TF (400V option), 16i/18i/21i.
Communication: FSSB fiber optic bus (100Mbps).
Feedback: Absolute/incremental encoders (αi pulse coder); built‑in backup capacitor (≈10‑minute hold, no homing after replacement).
Protection & Alarm Functions
Overcurrent (AL‑01): Main circuit overload or short circuit.
DC Bus Undervoltage (AL‑04) / Overvoltage (AL‑07)
Heatsink Overheat (AL‑03)
Fan Abnormal (AL‑02)
Encoder/Feedback Error
Regenerative Overload
Front‑panel 7‑segment LED displays real‑time status and alarm codes.
Installation Guidelines
De‑energize the entire system and perform lockout/tagout before installation.
Mount vertically on a cabinet plate; ensure ≥50mm clearance top and bottom for ventilation.
Connect DC bus terminals to αi PSM power supply; ensure reliable protective grounding.
Wire 24V control power and FSSB fiber cables per FANUC standard pinouts.
Verify all connections for tightness and correctness before restoring power; clear existing alarms before operation.
Safety Notice
High voltage present inside; wait ≥10 minutes after power‑off before opening the cover.
Installation, wiring, and maintenance must be performed by qualified professional electricians.
Use only genuine FANUC cables and connectors to avoid equipment damage and safety hazards.
Maintain unobstructed airflow to prevent overheating; clean fan and heat sink dust regularly, replace faulty cooling components promptly.
Key Features
2.8kW / 9.1A rated output for medium‑duty servo applications.
Compact 60mm width saves cabinet space.
Built‑in absolute encoder backup capacitor eliminates homing after replacement.
FSSB fiber communication ensures high‑speed, noise‑immune data transfer.
Low‑loss power devices reduce heat generation and energy consumption.
Get a Quote