A06B-6122-H045
Description
General Information
Model Identification
Part Number: A06B-6122-H045 (common variants: #H550, #H553, #H570)
Model: SPM‑45HVi (αi SP‑45HV)
Series: Alpha i (αi)
Type: High‑voltage spindle amplifier (400V AC)
Manufacturer: FANUC
Application: CNC spindle motor drive for medium‑to‑heavy‑duty machining.
Electrical Specifications
DC Bus Input (from PSM)
Voltage: 565–679V DC
Rated Input Power: 50kW
Control Power: External 24V DC ±10% (for logic, FSSB communication, and fan).
AC Output (to Spindle Motor)
Rated Output Voltage: 480V AC (3‑phase)
Rated Output Current: 100A
Output Frequency: Up to 400Hz (motor‑dependent)
Control Method: Full‑digital vector control (speed, position, torque modes).
Regenerative Capability
Supports regenerative braking (energy fed back to DC bus); works with αi PSM’s regenerative circuit.
Mechanical and Environmental Parameters
Construction: Metal housing with yellow front panel; vertical cabinet mounting.
Dimensions (W×H×D): Approximately 150mm × 350mm × 250mm
Weight: Approximately 12kg (26.5lbs)
Cooling: Built‑in replaceable axial fan + high‑efficiency heat sink.
Operating Temperature: 0°C to +55°C
Storage Temperature: ‑20°C to +70°C
Humidity: 5%–95% RH (non‑condensing)
Vibration: 0.5g (10–500Hz)
Protection Class: IP20 (for cabinet installation).
Compatibility
Spindle Motors: FANUC αi series high‑voltage spindle motors (e.g., αi45).
Power Supply: αi PSM series (400V‑class, e.g., A06B‑6120‑H075).
CNC Systems: FANUC 30i/31i/32i‑B, 0i‑MF/TF (400V option).
Communication: FSSB fiber optic bus (100Mbps, daisy‑chain capable).
Interface: Type B (complex) interface for spindle orientation, rigid tapping, and multi‑stage speed control.
Protection and Alarm Functions
Overcurrent (AL‑01): Main circuit overload or short circuit.
DC Bus Undervoltage (AL‑04) / Overvoltage (AL‑07).
Heatsink Overheat (AL‑03)
Fan Abnormal (AL‑02)
Input Phase Loss
Regenerative Overload
Front‑panel 7‑segment LED display shows power status, FSSB link, and alarm codes in real time.
Installation Guidelines
De‑energize the entire system and perform lockout/tagout before installation.
Mount vertically on a cabinet plate; ensure adequate ventilation space above and below.
Connect DC bus terminals to αi PSM power supply; ensure reliable protective grounding.
Wire 24V control power and FSSB fiber cables per FANUC standard pinouts.
Verify all connections for tightness and correctness before restoring power; clear existing alarms before operation.
Safety Notice
High voltage present inside; wait ≥10 minutes after power‑off before opening the cover.
Installation, wiring, and maintenance must be performed by qualified professional electricians.
Use only genuine FANUC cables and connectors to avoid equipment damage and safety hazards.
Maintain unobstructed airflow to prevent overheating; clean fan and heat sink dust regularly, replace faulty cooling components promptly.
Key Features
50kW high power output for medium‑to‑heavy‑duty spindle applications.
Full‑digital vector control ensures precise speed, position, and torque regulation.
Compact vertical design saves cabinet installation space.
FSSB fiber optic communication provides high‑speed, noise‑immune data transmission.
Comprehensive protection functions reduce unplanned downtime and enhance system reliability.
Get a Quote