A06B-6120-H045
Description
1. General Information
2. Model & Identification
Part Number:A06B-6120-H045
Type:αi PSM-45HVi (Power Supply Module, αiPS 45HV)
Series:Alpha i (αi)
Manufacturer:FANUC Corporation
Application:400–480V AC input, for high‑power servo/spindle drives in CNC & automation.
3. Electrical Specifications
Input
Voltage:3‑phase 400–480V AC, 50/60Hz.
Rated Current:92A @ 400V.
Input Power:45kW (max).
Output (DC Bus)
Voltage:565–679V DC.
Rated Power:50kW (continuous).
Regeneration:Built‑in regenerative circuit; returns braking energy to AC line, no external resistor needed for most cases.
Control Power
External 24V DC ±10% for control logic, FSSB communication, and fan.
4. Mechanical & Environmental
Construction:Heavy‑duty metal casing, yellow front panel, vertical panel‑mount design.
Dimensions:Approx. 170mm (W) × 380mm (H) × 272mm (D).
Weight:Approx. 10.7kg.
Cooling:Integrated axial fan (field‑replaceable) + high‑efficiency heat sink.
Operating Temperature:0°C to +55°C.
Storage Temperature:-20°C to +70°C.
Humidity:5%–95% RH (non‑condensing).
Vibration:0.5g (10–500Hz).
5. Compatibility
Servo Amplifiers:αi SVM series (400V class).
Spindle Amplifiers:αi SPM series (400V class).
CNC Systems:FANUC 30i/31i/32i‑B, 0i‑MF/TF (400V option).
Communication:FSSB (FANUC Serial Servo Bus) fiber‑optic interface; supports daisy‑chain connection.
6. Protection & Diagnostics
Overcurrent:Main circuit overcurrent/short‑circuit protection (AL‑01).
Overvoltage/Undervoltage:DC bus monitoring (AL‑04 undervoltage, AL‑07 overvoltage).
Overheat:Heat sink temperature monitoring (AL‑03).
Fan Fault:Fan stop/speed anomaly detection (AL‑02).
Phase Loss:Input phase loss protection (AL‑E).
Regeneration Error:Regenerative overload (AL‑438).
Status Indicators:Power, FSSB link, alarm LEDs on front panel.
7. Installation & Wiring
Power off the entire system and perform lockout/tagout to prevent electric shock.
Mount vertically on cabinet panel with four M5 screws; maintain 100mm clearance above and below for ventilation.
Connect 3‑phase AC input (L1/L2/L3) and ground PE terminal.
Connect DC bus output (DC+, DC‑) to servo/spindle amplifiers.
Connect 24V DC control power to CN1 connector.
Connect FSSB fiber cable to FSSB IN/OUT for CNC communication.
Verify all connections are secure before restoring power; check LED status and clear alarms.
8. Safety & Warnings
Warning:High voltage present inside; wait at least 10 minutes after power‑off before opening the cover.
Warning:Only qualified electrical personnel may perform installation, wiring, or maintenance.
Caution:Use only FANUC‑specified cables and connectors to avoid damage or fire.
Caution:Ensure proper ventilation to prevent overheating and premature failure.
Maintenance:Clean fan and heat sink every 3–6 months; replace faulty fans promptly.
9. Features & Benefits
High 50kW continuous DC power for demanding multi‑axis systems.
Full regeneration reduces energy consumption and heat generation.
Compact vertical design saves cabinet space.
HRV‑compatible FSSB communication ensures stable high‑speed data transfer.
Robust protection suite minimizes downtime in industrial environments.
Get a Quote