A06B-6110
May 22, 2026

A06B-6110

Part Number: A06B-6110-H006 (PSM-5.5i), H011 (PSM-11i), H015 (PSM-15i), H026 (PSM-26i), H037 (PSM-37i) Type: αi Series Power Supply Module (PSM) Manual: B-65282EN (αi Amplifier Description) Application: Feeds αi SVM/SPM servo/spindle amplifiers; compatible with 30i/31i/32i-B, R‑30iA, R‑J3iC Construction: Regenerative power supply, built-in cooling fan, FSSB fiber interface Protection: Overvoltage, overcurrent, overtemperature, phase loss, short circuit

Description

1. General Information

  • Part Number: A06B-6110-H006 (PSM-5.5i), H011 (PSM-11i), H015 (PSM-15i), H026 (PSM-26i), H037 (PSM-37i)

  • Type: αi Series Power Supply Module (PSM)

  • Manual: B-65282EN (αi Amplifier Description)

  • Application: Feeds αi SVM/SPM servo/spindle amplifiers; compatible with 30i/31i/32i-B, R‑30iA, R‑J3iC

  • Construction: Regenerative power supply, built-in cooling fan, FSSB fiber interface

  • Protection: Overvoltage, overcurrent, overtemperature, phase loss, short circuit


2. Electrical Ratings (200V 3φ)

Common Input

  • Input Voltage: AC 200–240V, 3φ, 50/60 Hz

  • Control Power: DC 24V ±10% (external or internal)

Model‑Specific Output

表格
ModelRated PowerDC Bus (V)Rated CurrentPeak Current
H006 (PSM‑5.5i)5.5 kW283–32510.5 A21 A
H011 (PSM‑11i)11 kW283–33920 A40 A
H015 (PSM‑15i)15 kW283–32527 A54 A
H026 (PSM‑26i)26 kW283–32547 A94 A
H037 (PSM‑37i)37 kW283–32567 A134 A

3. Mechanical & Environmental

  • Dimensions (W×H×D):

    • H006: 150 × 290 × 275 mm

    • H011/H015: 200 × 300 × 280 mm

  • Weight: 4.9 kg (H006) / 6.4 kg (H015)

  • Operating Temp: 0°C to +55°C

  • Storage Temp: −20°C to +60°C

  • Humidity: 5–95% RH (non‑condensing)

  • Protection Class: IP20 (indoor use)


4. Key Features

  • Regenerative Operation: Returns motor braking energy to the grid (saves energy vs. resistor regeneration)

  • FSSB Optical Communication: 100 Mbps fiber link to CNC/amplifiers; noise‑immune, daisy‑chain capable

  • Integrated 24V Supply: Auxiliary DC 24V (up to 10A) for I/O, sensors, and CNC control power

  • Hot‑Swap Fan: Replaceable cooling fan (A90L‑0001‑0441 for H006) without full disassembly

  • LED Diagnostics: 7‑segment display for alarm codes; PRDY/ALM status LEDs


5. Connector Layout

  • CX3: 3φ AC200–240V input

  • CX4: DC bus (+/−) output to SVM/SPM

  • CXA2A/CXA2B: DC24V out, *ESP (emergency stop), alarm output

  • FSSB IN/OUT: Fiber communication (CNC ↔ PSM ↔ SVM)

  • PE: Protective earth (heavy gauge)


6. Standard Alarm Codes (7‑segment)

  • AL‑1: Main circuit overcurrent

  • AL‑2: Cooling fan stopped

  • AL‑3: Heat sink overtemperature

  • AL‑4: DC bus undervoltage

  • AL‑5: Pre‑charge failure

  • AL‑6: Input power abnormal (phase loss)

  • AL‑7: DC bus overvoltage

  • AL‑E: Input open phase


7. Compatibility

  • CNC: 30i‑B, 31i‑B, 32i‑B, 0i‑MF/TF, R‑30iA, R‑J3iC

  • Servo Amplifiers: αi SVM (A06B‑610x‑Hxxx)

  • Spindle Amplifiers: αi SPM (A06B‑6111‑Hxxx)

  • Motors: αi‑S/αi‑F servo, αi spindle (200V)


8. Installation Notes

  • Mounting: Vertical only; ≥50 mm clearance top/bottom for airflow

  • Wiring: Separate power/control cables; shielded wires for encoders/FSSB

  • Grounding: PE to cabinet ground; star‑point grounding recommended


Get a Quote