A06B-6110
Description
1. General Information
Part Number: A06B-6110-H006 (PSM-5.5i), H011 (PSM-11i), H015 (PSM-15i), H026 (PSM-26i), H037 (PSM-37i)
Type: αi Series Power Supply Module (PSM)
Manual: B-65282EN (αi Amplifier Description)
Application: Feeds αi SVM/SPM servo/spindle amplifiers; compatible with 30i/31i/32i-B, R‑30iA, R‑J3iC
Construction: Regenerative power supply, built-in cooling fan, FSSB fiber interface
Protection: Overvoltage, overcurrent, overtemperature, phase loss, short circuit
2. Electrical Ratings (200V 3φ)
Common Input
Input Voltage: AC 200–240V, 3φ, 50/60 Hz
Control Power: DC 24V ±10% (external or internal)
Model‑Specific Output
| Model | Rated Power | DC Bus (V) | Rated Current | Peak Current |
|---|---|---|---|---|
| H006 (PSM‑5.5i) | 5.5 kW | 283–325 | 10.5 A | 21 A |
| H011 (PSM‑11i) | 11 kW | 283–339 | 20 A | 40 A |
| H015 (PSM‑15i) | 15 kW | 283–325 | 27 A | 54 A |
| H026 (PSM‑26i) | 26 kW | 283–325 | 47 A | 94 A |
| H037 (PSM‑37i) | 37 kW | 283–325 | 67 A | 134 A |
3. Mechanical & Environmental
Dimensions (W×H×D):
H006: 150 × 290 × 275 mm
H011/H015: 200 × 300 × 280 mm
Weight: 4.9 kg (H006) / 6.4 kg (H015)
Operating Temp: 0°C to +55°C
Storage Temp: −20°C to +60°C
Humidity: 5–95% RH (non‑condensing)
Protection Class: IP20 (indoor use)
4. Key Features
Regenerative Operation: Returns motor braking energy to the grid (saves energy vs. resistor regeneration)
FSSB Optical Communication: 100 Mbps fiber link to CNC/amplifiers; noise‑immune, daisy‑chain capable
Integrated 24V Supply: Auxiliary DC 24V (up to 10A) for I/O, sensors, and CNC control power
Hot‑Swap Fan: Replaceable cooling fan (A90L‑0001‑0441 for H006) without full disassembly
LED Diagnostics: 7‑segment display for alarm codes; PRDY/ALM status LEDs
5. Connector Layout
CX3: 3φ AC200–240V input
CX4: DC bus (+/−) output to SVM/SPM
CXA2A/CXA2B: DC24V out, *ESP (emergency stop), alarm output
FSSB IN/OUT: Fiber communication (CNC ↔ PSM ↔ SVM)
PE: Protective earth (heavy gauge)
6. Standard Alarm Codes (7‑segment)
AL‑1: Main circuit overcurrent
AL‑2: Cooling fan stopped
AL‑3: Heat sink overtemperature
AL‑4: DC bus undervoltage
AL‑5: Pre‑charge failure
AL‑6: Input power abnormal (phase loss)
AL‑7: DC bus overvoltage
AL‑E: Input open phase
7. Compatibility
CNC: 30i‑B, 31i‑B, 32i‑B, 0i‑MF/TF, R‑30iA, R‑J3iC
Servo Amplifiers: αi SVM (A06B‑610x‑Hxxx)
Spindle Amplifiers: αi SPM (A06B‑6111‑Hxxx)
Motors: αi‑S/αi‑F servo, αi spindle (200V)
8. Installation Notes
Mounting: Vertical only; ≥50 mm clearance top/bottom for airflow
Wiring: Separate power/control cables; shielded wires for encoders/FSSB
Grounding: PE to cabinet ground; star‑point grounding recommended
Get a Quote